Low voltage refers to the voltage with active value between the phases 1000 Volts and below. High voltage is the voltage with an active value above 1000 Volts. The voltage with an active value of 50 Volts or higher in alternating current and a voltage of 120 Volts or higher in direct current is dangerous. At high voltage, the hazard varies depending on the fault duration.
Low-voltage networks mainly consist of electrical lines extending from electricity distribution transformers to consumers. Low-voltage lines are easy to isolate and protect and are therefore generally installed close to consumers. However, power losses and voltage drops are high in low voltage transmissions. More than one hundred are used in distribution networks. The value determined for low voltage in our country is 220 Volt for consumers.
The Low Voltage Directive (2006 / 95 / AT) has been issued for the safety of electrical equipment used in homes and workplaces. This regulationApplies to all electrical devices and equipment with:
- Using alternating current between 50 and 1000 volts
- Using direct current between 75 and 1500 volts
In order to ensure electrical safety, the electrical devices and equipment described above must also bear the CE mark. Among these current values, enterprises producing electrical devices and equipment must manufacture in accordance with these legal regulations and the relevant standards issued by domestic and foreign organizations and affix CE marking on the products. Only then can these products be subject to free trade in European Union countries and world markets.
The purpose of the Low Voltage Regulation is to ensure the production and trade of electrical devices that are reliable, safe for the lives of all living beings and do not harm the environment. This regulation not only ensures the electrical safety, but also the mechanical and chemical safety of the products.
Our organization, UAF From the Accreditation Agency, Based on its accreditation authority in accordance with TS EN ISO / IEC 17025 standard, LVD performs low voltage tests within the scope of electrical safety tests.
About the Low Voltage Directive (LVD)
LVD covers the health and safety risks of electrical equipment operating with an input or output voltage, including:
50 and 1000 V for alternating current
75 and 1500 V for direct current
Applies to a wide range of electrical equipment for both consumer and professional use, for example:
- Household appliances
- Kablolar
- Power supply units
- Laser equipment
- Certain components, e.g. insurance
EU legislation in the electricity sector is important to ensure that the health and safety requirements across Europe are the same for products placed on the market.
The General Product Safety Directive (2001 / 95 / EC) covers consumer products that are under 50 V for alternating current or under 75 V for direct current. It aims to ensure that only safe consumer products are sold in the EU.
Publication of the chapters under the European Union harmonization legislation and references to harmonized standards;
ESO |
Reference and title of the standard |
Release date |
CEN |
AND 13637: 2015 Building equipment - Electrically controlled exit systems for use on escape routes - Requirements and test methods |
2016/08/07 |
CENELEC |
HD 308 S2: 2001 Identification of cores in cables and flexible cables |
2016/08/07 |
CENELEC |
HD 361 S3: 1999 Cable assignment system |
2016/08/07 |
|
HD 361 S3: 1999 / A1: 2006 |
2016/08/07 |
|
HD 361 S3: 1999 / AC: 1999 |
|
CENELEC |
HD 368 S1: 1978 Direct acting recording electrical measuring instruments and accessories IEC 60258: 1968 + A1: 1976 |
2016/08/07 |
CENELEC |
HD 549 S1: 1989 Conference systems - Electrical and audio requirements IEC 60914: 1988 |
2016/08/07 |
CENELEC |
HD 603 S1: 1994 Distribution cables with nominal voltage 0,6 / 1 kV |
2016/08/07 |
|
HD 603 S1: 1994 / A1: 1997 |
|
|
HD 603 S1: 1994 / A2: 2003 |
|
|
HD 603 S1: 1994 / A3: 2007 |
2016/08/07 |
CENELEC |
HD 604 S1: 1994 0,6 / 1 kV and 1,9 / 3,3 kV power cables with special fire performance for use in power stations |
2016/08/07 |
|
HD 604 S1: 1994 / A1: 1997 |
|
|
HD 604 S1: 1994 / A2: 2002 |
|
|
HD 604 S1: 1994 / A3: 2005 |
2016/08/07 |
CENELEC |
HD 605 S2: 2008 Electrical cables - Additional test methods |
2016/08/07 |
|
HD 605 S2: 2008 / AC: 2010 |
|
CENELEC |
HD 626 S1: 1996 Overhead distribution cables at rated voltage Uo / U (Um): 0,6 / 1 (1,2) kV |
2016/08/07 |
|
HD 626 S1: 1996 / A1: 1997 |
|
|
HD 626 S1: 1996 / A2: 2002 |
2016/08/07 |
CENELEC |
HD 627 S1: 1996 Multi-core and multi-wire cables for underground and underground installation |
2016/08/07 |
|
HD 627 S1: 1996 / A1: 2000 |
|
|
HD 627 S1: 1996 / A2: 2005 |
2016/08/07 |
CENELEC |
HD 639 S1: 2002 Electrical accessories - Portable residual current devices (PRCDs) without built-in overcurrent protection for household and similar uses IEC 61540: 1997 (Changed) + A1: 1998 (Changed) |
2016/08/07 |
|
HD 639 S1: 2002 / A1: 2003 |
|
|
HD 639 S1: 2002 / A2: 2010 |
2016/08/07 |
|
HD 639 S1: 2002 / AC: 2003 |
|
CENELEC |
AND 41003: 2008 Specific safety requirements for equipment to be connected to telecommunications networks and / or cable distribution systems |
2016/08/07 |
CENELEC |
EN 50065-4-2: 2001 Signaling in low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz - Part 4-2: Low voltage decoupling filters - Safety requirements |
2016/08/07 |
|
EN 50065-4-2: 2001 / A1: 2003 |
|
|
EN 50065-4-2: 2001 / A2: 2005 |
2016/08/07 |
CENELEC |
EN 50065-4-7: 2005 Signaling in low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz - Part 4-7: Portable low-voltage decoupling filters - Safety requirements |
2016/08/07 |
|
EN 50065-4-7: 2005 / AC: 2006 |
|
CENELEC |
IN 50085-1: 2005 Cable tray systems and cable tray systems for electrical installation - Part 1: General requirements |
2016/08/07 |
|
EN 50085-1: 2005 / A1: 2013 |
2016/08/07 |
CENELEC |
EN 50085-2-1: 2006 Cable tray systems and cable tray systems for electrical installation - Part 2-1: Cable tray systems and cable tray systems for installation in walls and ceilings |
2016/08/07 |
|
EN 50085-2-1: 2006 / A1: 2011 |
2016/08/07 |
CENELEC |
EN 50085-2-2: 2008 Wiring ducts for wiring systems and electrical wiring - Part 2-2: Particular requirements for wiring duct systems and wiring duct systems designed for installation in underground, sewer or ground |
2016/08/07 |
CENELEC |
EN 50085-2-3: 2010 Cable tray systems and cable tray systems for electrical installation - Part 2-3: Special requirements for corrugated cable tray systems designed for installation in cabinets |
2016/08/07 |
CENELEC |
EN 50085-2-4: 2009 Cable duct systems and cable duct systems for electrical installation - Part 2-4: Special requirements for service masts and service masts |
2016/08/07 |
CENELEC |
AND 50106: 2008 Safety of household and similar electrical appliances - Particular requirements for routine testing of devices covered by EN 60335-1 |
2016/08/07 |
CENELEC |
IN 50117-1: 2002 Coaxial cables - Part 1: General specifications |
2016/08/07 |
|
EN 50117-1: 2002 / A1: 2006 |
|
|
EN 50117-1: 2002 / A2: 2013 |
2016/08/07 |
CENELEC |
EN 50117-2-1: 2005 Coaxial cables - Part 2-1: Cross-sectional characteristics of cables used in wired distribution networks - 5 MHz - 1 Closed drop cables for systems operating at 000 MHz |
2016/08/07 |
|
EN 50117-2-1: 2005 / A1: 2008 |
|
|
EN 50117-2-1: 2005 / A2: 2013 |
2016/08/07 |
CENELEC |
EN 50117-2-2: 2004 Coaxial cables - Part 2-2: Cross-sectional characteristics of cables used in wired distribution networks - 5 MHz - 1 Open drop cables for systems operating at 000 MHz |
2016/08/07 |
|
EN 50117-2-2: 2004 / A1: 2008 |
|
|
EN 50117-2-2: 2004 / A2: 2013 |
2016/08/07 |
CENELEC |
EN 50117-2-3: 2004 Coaxial cables - Part 2-3: Cross-sectional characteristics of cables used in wired distribution networks - 5 MHz - 1 Distribution and trunk cables for systems operating at 000 MHz |
2016/08/07 |
|
EN 50117-2-3: 2004 / A1: 2008 |
|
|
EN 50117-2-3: 2004 / A2: 2013 |
2016/08/07 |
CENELEC |
EN 50117-2-4: 2004 Coaxial cables - Part 2-4: Cross-sectional specification for cables used in cable distribution networks - 5 MHz - 3 Closed drop cables for systems operating at 000 MHz |
2016/08/07 |
|
EN 50117-2-4: 2004 / A1: 2008 |
|
|
EN 50117-2-4: 2004 / A2: 2013 |
2016/08/07 |
CENELEC |
EN 50117-2-5: 2004 Coaxial cables - Part 2-5: Cross-sectional characteristics of the cables used in wired distribution networks - 5 MHz - 3 Open drop cables for systems operating at 000 MHz |
2016/08/07 |
|
EN 50117-2-5: 2004 / A1: 2008 |
|
|
EN 50117-2-5: 2004 / A2: 2013 |
2016/08/07 |
|
EN 50117-2-5: 2004 / AC: 2012 |
|
CENELEC |
EN 50117-3-1: 2002 Coaxial cables - Part 3-1: Cross-sectional characteristics of cables used in telecom applications - Miniature cables used in digital communication systems |
2016/08/07 |
CENELEC |
EN 50117-4-1: 2008 Coaxial cables - Part 4-1: Cross-sectional characteristics of cables for BCT cabling according to EN 50173 - 5 MHz - 3 Closed drop cables for systems operating at 000 MHz |
2016/08/07 |
|
EN 50117-4-1: 2008 / A1: 2013 |
2016/08/07 |
CENELEC |
EN 50117-4-2: 2015 Coaxial cables - Part 4-2: Cross-sectional specification for CATV cables up to 6 GHz for use in wired distribution networks |
2016/08/07 |
CENELEC |
IN 50156-1: 2015 Electrical equipment for furnaces and ancillary equipment - Part 1: Requirements for application design and installation |
2016/08/07 |
CENELEC |
IN 50156-2: 2015 Electrical equipment for furnaces and ancillary equipment - Part 2: Requirements for the design, development and type approval of safety devices and subsystems |
2016/08/07 |
CENELEC |
AND 50178: 1997 Electronic equipment for use in power installations |
2016/08/07 |
CENELEC |
AND 50214: 2006 Flexible cables with flat polyvinyl chloride sheath |
2016/08/07 |
|
EN 50214: 2006 / AC: 2007 |
|
CENELEC |
AND 50250: 2002 Converters for industrial use |
2016/08/07 |
|
EN 50250: 2002 / A1: 2015 |
2016/08/07 |
|
EN 50250: 2002 / AC: 2007 |
|
CENELEC |
AND 50274: 2002 Low-voltage switchgear and control devices - Protection against electric shock - Protection against unintended direct contact with dangerous live parts |
2016/08/07 |
|
EN 50274: 2002 / AC: 2009 |
|
CENELEC |
IN 50288-1: 2013 Multi-element metallic cables for analog and digital communication and control - Part 1: General features |
2016/08/07 |
CENELEC |
EN 50288-2-1: 2013 Multi-element metallic cables for analog and digital communication and control - Part 2-1: Cross-sectional features for shielded cables characterized by 100 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-2-2: 2013 Multi-element metallic cables for analog and digital communication and control - Part 2-2: Cross-sectional features for shielded cables characterized by 100 MHz - Work area and patch cable cables |
2016/08/07 |
CENELEC |
EN 50288-3-1: 2013 Multi-element metallic cables for analog and digital communication and control - Section 3-1: Cross-sectional characteristics of unshielded cables not characterized by 100 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-3-2: 2013 Multi-element metallic cables for analog and digital communication and control - Part 3-2: Cross-sectional features for unshielded cables not characterized by 100 MHz - Work area and connecting cable cables |
2016/08/07 |
CENELEC |
EN 50288-4-1: 2013 Multi-element metallic cables for analog and digital communication and control - Part 4-1: Sectional features for shielded cables - Up to 600 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-4-2: 2013 Multi-element metallic cables for analog and digital communication and control - Part 4-2: Sectional features for shielded cables - Up to 600 MHz - Working area and patch cable cables |
2016/08/07 |
CENELEC |
EN 50288-5-1: 2013 Multi-element metallic cables for analog and digital communication and control - Part 5-1: Cross-sectional features for screened cables up to 250 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-5-2: 2013 Multi-element metallic cables for analog and digital communication and control - Part 5-2: Cross-sectional features for shielded cables up to 250 MHz - Work area and patch cable cables |
2016/08/07 |
CENELEC |
EN 50288-6-1: 2013 Multi-element metallic cables for analog and digital communication and control - Section 6-1: Cross-sectional characteristics of colored, unshielded cables up to 250 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-6-2: 2013 Multicomponent metallic cables for analog and digital communication and control - Part 6-2: Cross-sectional features for unshielded, unshielded cables up to 250 MHz - Working area and connecting cable cables |
2016/08/07 |
CENELEC |
IN 50288-7: 2005 Multi-element metallic cables for analog and digital communication and control - Part 7: Cross-sectional properties for instrumentation and control cables |
2016/08/07 |
CENELEC |
IN 50288-8: 2012 Multi-element metallic cables for analog and digital communication and control - Part 8: Specification for type 2 cables characterized up to 1 MHz |
2016/08/07 |
CENELEC |
EN 50288-9-1: 2012 Multi-element metallic cables for analog and digital communication and control - Part 9-1: Cross-sectional features for screened cables up to 1000 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-9-2: 2015 Multicomponent metallic cables for analog and digital communication and control - Part 9-2: Cross-sectional features for 1 MHz to 1 000 MHz characterized for workspace, patch cable and data center applications |
2016/08/07 |
CENELEC |
EN 50288-10-1: 2012 Multi-element metallic cables for analog and digital communication and control - Part 10-1: Cross-sectional features for shielded cables characterized by 500 MHz - Horizontal floor and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-10-2: 2015 Multicomponent metallic cables for analog and digital communication and control - Part 10-2: Cross-sectional features for 1 MHz to 500 MHz characterized for workspace, patch cable and data center applications |
2016/08/07 |
CENELEC |
EN 50288-11-1: 2012 Multi-element metallic cables for analog and digital communication and control - Part 11-1: Cross-sectional characteristics of unshielded cables up to 500 MHz - Horizontal and building backbone cables |
2016/08/07 |
CENELEC |
EN 50288-11-2: 2015 Multi-element metallic cables for analog and digital communication and control - Part 11-2: Cross-sectional features for unfiltered cables from 1 MHz to 500 MHz for work area, patch cord and data center applications |
2016/08/07 |
CENELEC |
EN 50289-1-3: 2001 Communication cables - Technical specifications for test methods - Part 1-3: Electrical test methods - Dielectric strength |
2016/08/07 |
CENELEC |
EN 50289-1-4: 2001 Communication cables - Specification for test methods - Part 1-4: Electrical test methods - Insulation resistance |
2016/08/07 |
CENELEC |
EN 50290-2-1: 2005 Communication cables - Part 2-1: Common design rules and construction |
2016/08/07 |
CENELEC |
EN 50290-2-20: 2001 Communication cables - Part 2-20: Common design rules and construction - General |
2016/08/07 |
CENELEC |
EN 50290-2-21: 2001 Communication cables - Part 2-21: Common design rules and construction - PVC insulation compounds |
2016/08/07 |
|
EN 50290-2-21: 2001 / A1: 2007 |
2016/08/07 |
|
EN 50290-2-21: 2001 / A1 |
|
|
EN 50290-2-21: 2001 / AC: 2003 |
|
CENELEC |
EN 50290-2-22: 2001 Communication cables - Part 2-22: Common design rules and structure - PVC coating components |
2016/08/07 |
|
EN 50290-2-22: 2001 / A1: 2007 |
2016/08/07 |
CENELEC |
EN 50290-2-23: 2013 Communication cables - Part 2-23: Common design rules and construction - Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables |
2016/08/07 |
CENELEC |
EN 50290-2-24: 2002 Communication cables - Part 2-24: Common design guidelines and construction - PE sheath |
2016/08/07 |
|
EN 50290-2-24: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 50290-2-25: 2013 Communication cables - Part 2-25: Common design rules and construction - Polypropylene insulation compounds |
2016/08/07 |
CENELEC |
EN 50290-2-26: 2002 Communication cables - Part 2-26: Common design rules and structure - Halogen-free flame retardant insulation compounds |
2016/08/07 |
|
EN 50290-2-26: 2002 / A1: 2007 |
2016/08/07 |
CENELEC |
EN 50290-2-27: 2002 Communication cables - Part 2-27: Common design rules and structure - Halogen-free flame retardant thermoplastic sheath components |
2016/08/07 |
|
EN 50290-2-27: 2002 / A1: 2007 |
2016/08/07 |
|
EN 50290-2-27: 2002 / A1 |
|
CENELEC |
EN 50290-2-28: 2002 Communication cables - Part 2-28: Common design rules and construction - Filling compounds for filled cables |
2016/08/07 |
CENELEC |
EN 50290-2-29: 2002 Communication cables - Part 2-29: Common design rules and construction - Cross-linked PE insulation compounds |
2016/08/07 |
CENELEC |
EN 50290-2-30: 2002 Communication cables - Part 2-30: Common design rules and structure - Poly (tetrafluoroethylene-hexafluoropropylene) (FEP) insulation and sheath |
2016/08/07 |
CENELEC |
EN 50290-4-1: 2014 Communication cables - Part 4-1: General considerations for the use of cables - Environmental conditions and safety considerations |
2016/08/07 |
CENELEC |
EN 50290-4-2: 2014 Communication cables - Part 4-2: General information on handling cables - User guide |
2016/08/07 |
CENELEC |
IN 50363-0: 2011 Insulation, coating and coating materials for low-voltage power cables - Part 0: General introduction |
2016/08/07 |
CENELEC |
IN 50363-1: 2005 Insulation, coating and coating materials for low voltage power cables - Part 1: Cross-linked elastomeric insulation compounds |
2016/08/07 |
CENELEC |
EN 50363-2-1: 2005 Insulation, sheathing and covering materials for low voltage power cables - Part 2-1: Cross-linked elastomeric sheath components |
2016/08/07 |
|
EN 50363-2-1: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
EN 50363-2-2: 2005 Insulation, coating and coating materials for low voltage power cables - Part 2-2: Cross-linked elastomeric coating compounds |
2016/08/07 |
CENELEC |
IN 50363-3: 2005 Insulation, coating and coating materials for low voltage power cables - Part 3: PVC insulation compounds |
2016/08/07 |
|
EN 50363-3: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
EN 50363-4-1: 2005 Insulation, sheathing and covering materials for low voltage power cables - Part 4-1: PVC coating components |
2016/08/07 |
CENELEC |
EN 50363-4-2: 2005 Insulation, sheathing and covering materials for low voltage power cables - Part 4-2: PVC coating compounds |
2016/08/07 |
CENELEC |
IN 50363-5: 2005 Insulation, coating and coating materials for low voltage power cables - Part 5: Halogen-free, cross-linked insulation compounds |
2016/08/07 |
|
EN 50363-5: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
IN 50363-6: 2005 Insulation, coating and coating materials for low voltage power cables - Part 6: Halogen-free, cross-linked coating components |
2016/08/07 |
|
EN 50363-6: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
IN 50363-7: 2005 Insulation, coating and coating materials for low voltage power cables - Part 7: Halogen-free, thermoplastic insulation compounds |
2016/08/07 |
CENELEC |
IN 50363-8: 2005 Insulation, sheathing and covering materials for low voltage power cables - Part 8: Halogen-free thermoplastic sheaths |
2016/08/07 |
|
EN 50363-8: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
EN 50363-9-1: 2005 Insulation, sheathing and covering materials for low voltage power cables - Part 9-1: Miscellaneous insulation materials - Cross-linked polyvinyl chloride (XLPVC) |
2016/08/07 |
CENELEC |
EN 50363-10-1: 2005 Insulation, coating and coating materials for low voltage power cables - Part 10-1: Various sheath components - Cross-linked polyvinyl chloride (XLPVC) |
2016/08/07 |
CENELEC |
EN 50363-10-2: 2005 Insulation, coating and coating materials for low voltage power cables - Part 10-2: Miscellaneous coating materials - Thermoplastic polyurethane |
2016/08/07 |
CENELEC |
AND 50364: 2010 Limiting human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz to 300 GHz used in Electronic Material Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications |
2016/08/07 |
CENELEC |
AND 50369: 2005 Liquid-proof jacket systems for cable management |
2016/08/07 |
CENELEC |
AND 50395: 2005 Electrical test methods for low voltage power cables |
2016/08/07 |
|
EN 50395: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
AND 50396: 2005 Non-electrical test methods for low-voltage power cables |
2016/08/07 |
|
EN 50396: 2005 / A1: 2011 |
2016/08/07 |
CENELEC |
IN 50406-1: 2004 End-user multi-pair cables used in high-speed telecommunications networks - Part 1: Antenna cables |
2016/08/07 |
CENELEC |
IN 50406-2: 2004 End-user multi-pair cables used in high-bit-speed telecommunications networks - Part 2: Duct and embedded cables |
2016/08/07 |
CENELEC |
IN 50407-1: 2004 Multi-pair cables for use in high bit rate digital access telecommunications networks - Part 1: Outdoor cables |
2016/08/07 |
CENELEC |
IN 50407-3: 2014 Multi-pair cables for use in high bit rate digital access telecommunications networks - Part 3: Closed multiple dual / quad amplifier cables up to 100 MHz for maximum service connectivity Applications up to 100 m, xDSL and 100 Mbit / s supporting universal services IP |
2016/08/07 |
CENELEC |
AND 50428: 2005 Switches for household and similar fixed electrical installations - Guarantee standard - Switches and related accessories for use in home and building electronic systems (HBES) |
2016/08/07 |
|
EN 50428: 2005 / A1: 2007 |
|
|
EN 50428: 2005 / A2: 2009 |
2016/08/07 |
CENELEC |
IN 50441-1: 2012 Cables for indoor residential telecommunications installations - Part 1: Unshielded cables - Class 1 |
2016/08/07 |
CENELEC |
IN 50441-2: 2012 Cables for indoor residential telecommunications installations - Part 2: Shielded cables - Class 1 |
2016/08/07 |
CENELEC |
IN 50441-3: 2006 Cables for indoor residential telecommunications installations - Part 3: Shielded cables - Class 3 |
2016/08/07 |
CENELEC |
IN 50441-4: 2012 Cables for indoor residential telecommunications installations - Part 4: 1 200 Cables up to MHz - 3. Class |
2016/08/07 |
CENELEC |
AND 50445: 2008 Product family standard (0 Hz to 300 GHz) to demonstrate compliance of equipment with basic restrictions on exposure to electromagnetic fields for resistance welding, arc welding and allied processes |
2016/08/07 |
CENELEC |
IN 50491-3: 2009 General Requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements |
2016/08/07 |
CENELEC |
EN 50491-4-1: 2012 General Requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 4-1: General functional safety requirements for products intended for integration into Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) |
2016/08/07 |
CENELEC |
EN 50491-6-1: 2014 General Requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 6-1: HBES installations - Installation and planning |
2016/08/07 |
CENELEC |
AND 50497: 2007 Recommended test method for assessing the risk of plasticizing exudation from PVC insulated and sheathed cables |
2016/08/07 |
CENELEC |
AND 50520: 2009 Cover plates and cover tapes for protection of buried cables or buried conduits in underground installations and for location warning |
2016/08/07 |
CENELEC |
IN 50525-1: 2011 Power cables - Low voltage power cables from nominal voltages up to and including 450 / 750 V (U0 / U) - Part 1: General requirements |
2016/08/07 |
CENELEC |
EN 50525-2-11: 2011 Power cables - Low-voltage power cables up to and including the nominal voltages 450 / 750 V (Uo / U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation |
2016/08/07 |
CENELEC |
EN 50525-2-12: 2011 Electrical cables - Low voltage power cables up to 450 / 750 V (Uo / U) and rated voltages - Part 2-12: Cables for general applications - Thermoplastic PVC insulated cables for extensible cables |
2016/08/07 |
CENELEC |
EN 50525-2-21: 2011 Power cables - Low voltage power cables up to and including the nominal voltages 450 / 750 V (Uo / U) - Part 2-21: Cables for general applications - Flexible cables with cross-linked elastomeric insulation |
2016/08/07 |
|
EN 50525-2-21: 2011 / AC: 2013 |
|
CENELEC |
EN 50525-2-22: 2011 Power cables - Low voltage power cables with nominal voltages up to 450 / 750 V (U0 / U) - Part 2-22: Cables for general applications - High flexibility braided cables with cross-linked elastomeric insulation |
2016/08/07 |
CENELEC |
EN 50525-2-31: 2011 Power cables - Low voltage power cables up to 450 / 750 V (U0 / U) and rated voltages - Part 2-31: Cables for general applications - Single core, unshielded cables with thermoplastic PVC insulation |
2016/08/07 |
CENELEC |
EN 50525-2-41: 2011 Power cables - Low voltage power cables up to 450 / 750 V (U0 / U) and rated voltages - Part 2-41: Cables for general applications - Single core cables with cross-linked silicone rubber insulation |
2016/08/07 |
CENELEC |
EN 50525-2-42: 2011 Power cables - Low voltage power cables with nominal voltages up to and including 450 / 750 V (U0 / U) - Part 2-42: Cables for general applications - Single-core, unshielded cables with EVA insulation |
2016/08/07 |
CENELEC |
EN 50525-2-51: 2011 Power cables - Low voltage power cables up to 450 / 750 V (U0 / U) and rated voltages - Part 2-51: Cables for general applications - Thermoplastic insulated oil resistant control cables |
2016/08/07 |
CENELEC |
EN 50525-2-71: 2011 Power cables - Low-voltage power cables up to and including the nominal voltages 450 / 750 V (U0 / U) - Part 2-71: Cables for general applications - Flat stranded cables with thermoplastic PVC insulation (cables) |
2016/08/07 |
CENELEC |
EN 50525-2-72: 2011 Electrical cables - Power cables up to 450 / 750 V (U0 / U) and rated voltages from low voltage - Part 2-72: Cables for general applications - Flat split cables (thermoplastic PVC insulated) |
2016/08/07 |
CENELEC |
EN 50525-2-81: 2011 Power cables - Low voltage power cables up to 450 / 750 V (U0 / U) and rated voltages - Part 2-81: Cables for general applications - Cables with cross-linked elastomeric coating for arc welding |
2016/08/07 |
CENELEC |
EN 50525-2-82: 2011 Power cables - Power cables from nominal voltages up to 450 / 750 V (U0 / U) and low voltage - Part 2-82: Cables for general applications - Crosslinked elastomeric insulated cables for decorative chains |
2016/08/07 |
CENELEC |
EN 50525-2-83: 2011 Power cables - Low voltage power cables from nominal voltages up to and including 450 / 750 V (U0 / U) - Part 2-83: Cables for general applications - Multi-core cables with cross-linked silicone rubber insulation |
2016/08/07 |
CENELEC |
EN 50525-3-11: 2011 Power cables - Low voltage power cables up to and including the nominal voltages 450 / 750 V (U0 / U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation and low smoke emission |
2016/08/07 |
CENELEC |
EN 50525-3-21: 2011 Power cables - Low voltage power cables up to and including the nominal voltages 450 / 750 V (U0 / U) - Part 3-21: Cables with special fire performance - Halogen-free cross-linked insulation and flexible cables with low smoke emission |
2016/08/07 |
|
EN 50525-3-21: 2011 / AC: 2013 |
|
CENELEC |
EN 50525-3-31: 2011 Power cables - Low voltage power cables up to and including the nominal voltages 450 / 750 V (U0 / U) - Part 3-31: Cables with special fire performance - Single core, unshielded cables with halogen-free thermoplastic insulation and low smoke emissions |
2016/08/07 |
CENELEC |
EN 50525-3-41: 2011 Power cables - Low voltage power cables up to and including the nominal voltages 450 / 750 V (U0 / U) - Part 3-41: Cables with special fire performance - Halogen-free cross-linked insulated, single core, unshielded cables and low smoke emissions |
2016/08/07 |
CENELEC |
IN 50539-11: 2013 Low-voltage surge protective devices - Surge protective devices for special applications, including DC - Part 11: Requirements and tests for SPDs in photovoltaic applications |
2016/08/07 |
|
EN 50539-11: 2013 / A1: 2014 |
2016/08/07 |
CENELEC |
AND 50550: 2011 Power frequency surge protection device (POP) for household and similar applications |
2016/08/07 |
|
EN 50550: 2011 / A1: 2014 |
2016/08/07 |
|
EN 50550: 2011 / AC: 2012 |
|
CENELEC |
AND 50556: 2011 Road Traffic Signal Systems |
2016/08/07 |
CENELEC |
AND 50557: 2011 Requirements for automatic reclosure devices (ARDs) for circuit breakers, RCBOs-RCCBs for domestic and similar uses |
2016/08/07 |
CENELEC |
IN 50565-1: 2014 Power cables - Operating instructions for cables with rated voltage not exceeding 450 / 750 V (U0 / U) - Part 1: General guidance |
2016/08/07 |
CENELEC |
IN 50565-2: 2014 Electrical cables - Operating instructions for cables whose nominal voltage does not exceed 450 / 750 V (U0 / U) - Part 2: Specific guidelines for EN 50525 cable types |
2016/08/07 |
CENELEC |
AND 50615: 2015 Household and similar electrical appliances - Safety - Special requirements for fire prevention and suppression devices for electric cookers (cookers) |
2016/08/07 |
CENELEC |
AND 50618: 2014 Electrical cables for photovoltaic systems |
2016/08/07 |
CENELEC |
IN 60034-1: 2010 Rotating electric machines - Part 1: Rating and performance IEC 60034-1: 2010 (Changed) |
2016/08/07 |
|
EN 60034-1: 2010 / AC: 2010 |
|
CENELEC |
IN 60034-5: 2001 Rotating electrical machines - Part 5: Degree of protection provided by the integrated design of rotating electrical machines (IP code) - Classification IEC 60034-5: 2000 |
2016/08/07 |
|
EN 60034-5: 2001 / A1: 2007 IEC 60034-5: 2000 / A1: 2006 |
2016/08/07 |
CENELEC |
IN 60034-6: 1993 Rotating electrical machines - Part 6: Cooling methods (IC Code) IEC 60034-6: 1991 |
2016/08/07 |
CENELEC |
IN 60034-7: 1993 Rotating electrical machines - Part 7: Classification of construction types, mounting arrangements and terminal box position (IM Code) IEC 60034-7: 1992 |
2016/08/07 |
|
EN 60034-7: 1993 / A1: 2001 IEC 60034-7: 1992 / A1: 2000 |
2016/08/07 |
CENELEC |
IN 60034-8: 2007 Rotating electrical machines - Part 8: Terminal signs and direction of rotation IEC 60034-8: 2007 |
2016/08/07 |
|
EN 60034-8: 2007 / A1: 2014 IEC 60034-8: 2007 / A1: 2014 |
2016/08/07 |
CENELEC |
IN 60034-9: 2005 Rotating electrical machines - Part 9: Noise limits IEC 60034-9: 2003 (Replaced) |
2016/08/07 |
|
EN 60034-9: 2005 / A1: 2007 IEC 60034-9: 2003 / A1: 2007 |
2016/08/07 |
CENELEC |
IN 60034-11: 2004 Rotary electric machines - Part 11: Thermal protection IEC 60034-11: 2004 |
2016/08/07 |
CENELEC |
IN 60034-12: 2002 Rotating electric machines - Part 12: Initial performance of single-speed three-phase cage induction motors IEC 60034-12: 2002 |
2016/08/07 |
|
EN 60034-12: 2002 / A1: 2007 IEC 60034-12: 2002 / A1: 2007 |
2016/08/07 |
CENELEC |
IN 60034-14: 2004 Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights of mm and higher - Measurement, evaluation and limits of vibration intensity IEC 60034-14: 2003 |
2016/08/07 |
|
EN 60034-14: 2004 / A1: 2007 IEC 60034-14: 2003 / A1: 2007 |
2016/08/07 |
CENELEC |
IN 60051-2: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 2: Particular requirements for ammeters and voltmeters IEC 60051-2: 1984 |
2016/08/07 |
CENELEC |
IN 60051-3: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 3: Special requirements for wattmeters and variables IEC 60051-3: 1984 |
2016/08/07 |
|
EN 60051-3: 1989 / A1: 1995 IEC 60051-3: 1984 / A1: 1994 |
2016/08/07 |
CENELEC |
IN 60051-4: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 4: Particular requirements for frequency measuring instruments IEC 60051-4: 1984 |
2016/08/07 |
CENELEC |
IN 60051-5: 1989 Analog electrical measuring instruments and accessories for direct operation - Part 5: Particular requirements for phase meters, power factor and synchroscopes IEC 60051-5: 1985 |
2016/08/07 |
CENELEC |
IN 60051-6: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 6: Special requirements for ohmmeters and conductivity meters IEC 60051-6: 1984 |
2016/08/07 |
CENELEC |
IN 60051-7: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 7: Special requirements for multi-function instruments IEC 60051-7: 1984 |
2016/08/07 |
CENELEC |
IN 60051-8: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 8: Special requirements for accessories IEC 60051-8: 1984 |
2016/08/07 |
CENELEC |
IN 60051-9: 1989 Direct acting analogue electrical measuring instruments and accessories - Part 9: Recommended test methods IEC 60051-9: 1988 |
2016/08/07 |
|
EN 60051-9: 1989 / A1: 1995 IEC 60051-9: 1988 / A1: 1994 |
|
|
EN 60051-9: 1989 / A2: 1995 IEC 60051-9: 1988 / A2: 1995 |
2016/08/07 |
CENELEC |
IN 60110-1: 1998 Power capacitors for induction heating installations - Part 1: General IEC 60110-1: 1998 |
2016/08/07 |
CENELEC |
IN 60127-1: 2006 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse connections IEC 60127-1: 2006 |
2016/08/07 |
|
EN 60127-1: 2006 / A1: 2011 IEC 60127-1: 2006 / A1: 2011 |
|
|
EN 60127-1: 2006 / A2: 2015 IEC 60127-1: 2006 / A2: 2015 |
2016/08/07 |
CENELEC |
IN 60127-2: 2014 Miniature fuses - Section 2: Cartridge fuse links IEC 60127-2: 2014 |
2016/08/07 |
CENELEC |
IN 60127-4: 2005 Miniature fuses - Part 4: Universal modular fuse connections (UMF) - Transition and surface mounting types IEC 60127-4: 2005 |
2016/08/07 |
|
EN 60127-4: 2005 / A1: 2009 IEC 60127-4: 2005 / A1: 2008 |
|
|
EN 60127-4: 2005 / A2: 2013 IEC 60127-4: 2005 / A2: 2012 |
2016/08/07 |
CENELEC |
IN 60127-6: 2014 Miniature fuses - Part 6: Fuse holders for miniature fuse connections IEC 60127-6: 2014 |
2016/08/07 |
CENELEC |
IN 60127-7: 2016 Miniature fuses - Section 7: Miniature fuse connections for special applications IEC 60127-7: 2015 |
2016/08/07 |
CENELEC |
IN 60143-2: 2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks IEC 60143-2: 2012 |
2016/08/07 |
CENELEC |
AND 60155: 1995 Glow starters for fluorescent lamps IEC 60155: 1993 |
2016/08/07 |
|
EN 60155: 1995 / A1: 1995 IEC 60155: 1993 / A1: 1995 |
|
|
EN 60155: 1995 / A2: 2007 IEC 60155: 1993 / A2: 2006 |
2016/08/07 |
CENELEC |
IN 60204-1: 2006 Machine safety - Electrical equipment of machines - Part 1: General requirements IEC 60204-1: 2005 (Replaced) |
2016/08/07 |
|
EN 60204-1: 2006 / A1: 2009 IEC 60204-1: 2005 / A1: 2008 |
2016/08/07 |
|
EN 60204-1: 2006 / AC: 2010 |
|
CENELEC |
IN 60204-32: 2008 Machine safety - Electrical equipment of machines - Part 32: Requirements for lifting machines IEC 60204-32: 2008 |
2016/08/07 |
CENELEC |
AND 60215: 1989 Safety requirements for radio transmission equipment IEC 60215: 1987 |
2016/08/07 |
|
EN 60215: 1989 / A1: 1992 IEC 60215: 1987 / A1: 1990 |
|
|
EN 60215: 1989 / A2: 1994 IEC 60215: 1987 / A2: 1993 |
2016/08/07 |
CENELEC |
AND 60228: 2005 Conductors of insulated cables IEC 60228: 2004 |
2016/08/07 |
|
EN 60228: 2005 / AC: 2005 |
|
CENELEC |
AND 60238: 2004 Edison screw lampshades IEC 60238: 2004 |
2016/08/07 |
|
EN 60238: 2004 / A1: 2008 IEC 60238: 2004 / A1: 2008 |
|
|
EN 60238: 2004 / A2: 2011 IEC 60238: 2004 / A2: 2011 |
2016/08/07 |
|
EN 60238: 2004 / AC: 2005 |
|
CENELEC |
IN 60252-1: 2011 AC motor capacitors - Part 1: General - Performance, testing and evaluation - Safety requirements - Installation and operating instructions IEC 60252-1: 2010 |
2016/08/07 |
|
EN 60252-1: 2011 / A1: 2013 IEC 60252-1: 2010 / A1: 2013 |
2016/08/07 |
CENELEC |
IN 60252-2: 2011 AC Motor Capacitors - Part 2: Motor Starter Capacitors IEC 60252-2: 2010 |
2016/08/07 |
|
EN 60252-2: 2011 / A1: 2013 IEC 60252-2: 2010 / A1: 2013 |
2016/08/07 |
CENELEC |
IN 60255-27: 2014 Measuring relays and protection equipment - Part 27: Product safety requirements IEC 60255-27: 2013 |
2016/08/07 |
CENELEC |
IN 60269-1: 2007 Low voltage fuses - Part 1: General requirements IEC 60269-1: 2006 |
2016/08/07 |
|
EN 60269-1: 2007 / A1: 2009 IEC 60269-1: 2006 / A1: 2009 |
|
|
EN 60269-1: 2007 / A2: 2014 IEC 60269-1: 2006 / A2: 2014 |
2016/08/07 |
CENELEC |
HD 60269-2: 2013 Low voltage fuses - Part 2: Additional requirements for fuses for use by authorized persons (mainly fuses for industrial application) - Examples of standardized fuses A to K systems IEC 60269-2: 2013 (Changed) |
2016/08/07 |
CENELEC |
HD 60269-3: 2010 Low voltage fuses - Part 3: Additional requirements for fuses used by unqualified persons (mostly fuses for household and similar applications) - Examples of standardized fuses A to F systems IEC 60269-3: 2010 (Replaced) |
2016/08/07 |
|
HD 60269-3: 2010 / A1: 2013 IEC 60269-3: 2010 / A1: 2013 |
2016/08/07 |
CENELEC |
IN 60269-4: 2009 Low voltage fuses - Part 4: Additional requirements for fuse connections for the protection of semiconductor devices IEC 60269-4: 2009 |
2016/08/07 |
|
EN 60269-4: 2009 / A1: 2012 IEC 60269-4: 2009 / A1: 2012 |
|
CENELEC |
IN 60269-6: 2011 Low-voltage fuses - Part 6: Additional requirements for fuse connections for the protection of solar photovoltaic energy systems IEC 60 IEC 60269-6: 2010 |
2016/08/07 |
CENELEC |
IN 60309-1: 1999 Plugs, sockets and connectors for industrial purposes - Part 1: General requirements IEC 60309-1: 1999 |
2016/08/07 |
|
EN 60309-1: 1999 / A1: 2007 IEC 60309-1: 1999 / A1: 2005 (Replaced) |
|
|
EN 60309-1: 1999 / A2: 2012 IEC 60309-1: 1999 / A2: 2012 |
2016/08/07 |
|
EN 60309-1: 1999 / A1: 2007 / AC: 2014 |
|
CENELEC |
IN 60309-2: 1999 Plugs, sockets and couplers for industrial purposes - Part 2: Dimensional variability requirements for pin and contact tube accessories IEC 60309-2: 1999 |
2016/08/07 |
|
EN 60309-2: 1999 / A1: 2007 IEC 60309-2: 1999 / A1: 2005 (Modified) |
|
|
EN 60309-2: 1999 / A2: 2012 IEC 60309-2: 1999 / A2: 2012 |
2016/08/07 |
CENELEC |
IN 60309-4: 2007 Plugs, sockets and couplers for industrial purposes - Part 4: Switched sockets and connectors with or without prism IEC 60309-4: 2006 (Changed) |
2016/08/07 |
|
EN 60309-4: 2007 / A1: 2012 IEC 60309-4: 2006 / A1: 2012 |
2016/08/07 |
CENELEC |
IN 60320-1: 2001 Device adapters for household and similar general purposes - Part 1: General requirements IEC 60320-1: 2001 |
2016/08/07 |
|
EN 60320-1: 2001 / A1: 2007 IEC 60320-1: 2001 / A1: 2007 |
2016/08/07 |
CENELEC |
EN 60320-2-1: 2000 Device couplers for household and similar general purposes - Part 2-1: Sewing machine couplers IEC 60320-2-1: 2000 |
2016/08/07 |
CENELEC |
EN 60320-2-2: 1998 Device couplers for household and similar general purposes - Part 2-2: Interconnect coupler for household and similar equipment IEC 60320-2-2: 1998 |
2016/08/07 |
CENELEC |
EN 60320-2-4: 2006 Device couplers for household and similar general purposes - Part 2-4: Device adapters depending on the weight of the device for sighting IEC 60320-2-4: 2005 |
2016/08/07 |
|
EN 60320-2-4: 2006 / A1: 2009 IEC 60320-2-4: 2005 / A1: 2009 |
2016/08/07 |
CENELEC |
EN 60332-1-1: 2004 Tests on electrical and fiber optic cables under fire conditions - Part 1-1: Vertical flame spread test for single insulated wire or cable - Apparatus IEC 60332-1-1: 2004 |
2016/08/07 |
|
EN 60332-1-1: 2004 / A1: 2015 IEC 60332-1-1: 2004 / A1: 2015 |
2016/08/07 |
CENELEC |
EN 60332-1-2: 2004 Tests on electrical and fiber optic cables under fire conditions - Part 1-2: Vertical flame spread test for single insulated wire or cable - Procedure for 1 kW pre-mixed flame IEC 60332-1-2: 2004 |
2016/08/07 |
|
EN 60332-1-2: 2004 / A1: 2015 IEC 60332-1-2: 2004 / A1: 2015 |
2016/08/07 |
CENELEC |
EN 60332-1-3: 2004 Tests on electrical and fiber optic cables under fire conditions - Part 1-3: Vertical flame propagation test for single insulated wire or cable - Procedure for identification of flamed droplets / particles IEC 60332-1-3: 2004 |
2016/08/07 |
CENELEC |
EN 60332-2-1: 2004 Tests on electrical and fiber optic cables under fire conditions - Part 2-1: Vertical flame spread test for a single small insulated wire or cable - Apparatus IEC 60332-2-1: 2004 |
2016/08/07 |
CENELEC |
EN 60332-2-2: 2004 Tests on electrical and fiber optic cables under fire conditions - Part 2-2: Vertical flame propagation test for a single small insulated wire or cable - Procedure for diffusion flame IEC 60332-2-2: 2004 |
2016/08/07 |
CENELEC |
EN 60332-3-10: 2009 Tests on electrical and fiber optic cables under fire conditions - Part 3-10: Test for vertical flame propagation of vertically mounted bundled wires or cables - Apparatus IEC 60332-3-10: 2000 + A1: 2008 |
2016/08/07 |
CENELEC |
EN 60332-3-21: 2009 Tests on electrical and fiber optic cables in fire conditions - Part 3-21: Test for vertical flame spread of vertically mounted bundled cables or cables - Category AF / R IEC 60332-3-21: 2000 (Replaced) |
2016/08/07 |
CENELEC |
EN 60332-3-22: 2009 Tests on electrical and fiber optic cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically mounted bundled cables or cables - Category A IEC 60332-3-22: 2000 + A1: 2008 |
2016/08/07 |
CENELEC |
EN 60332-3-23: 2009 Tests on electrical and fiber optic cables under fire conditions - Part 3-23: Test for vertical flame propagation of vertically mounted bundled wires or cables - Category B IEC 60332-3-23: 2000 + A1: 2008 |
2016/08/07 |
CENELEC |
EN 60332-3-24: 2009 Tests on electrical and fiber optic cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically mounted bundled cables or cables - Category C IEC 60332-3-24: 2000 + A1: 2008 |
2016/08/07 |
CENELEC |
EN 60332-3-25: 2009 Tests on electrical and fiber optic cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically mounted bundled cables or cables - Category D IEC 60332-3-25: 2000 + A1: 2008 |
2016/08/07 |
CENELEC |
IN 60335-1: 2012 Household and similar electrical appliances - Safety - Part 1: General requirements IEC 60335-1: 2010 (Replaced) |
2016/08/07 |
|
EN 60335-1: 2012 / A11: 2014 |
2016/08/07 |
|
EN 60335-1: 2012 / AC: 2014 |
|
CENELEC |
EN 60335-2-2: 2010 Household and similar electrical appliances - Safety - Part 2-2: Special requirements for vacuum cleaners and water suction cleaners IEC 60335-2-2: 2009 |
2016/08/07 |
|
EN 60335-2-2: 2010 / A1: 2013 IEC 60335-2-2: 2009 / A1: 2012 |
|
|
EN 60335-2-2: 2010 / A11: 2012 |
2016/08/07 |
CENELEC |
EN 60335-2-3: 2016 Household and similar electrical appliances - Safety - Part 2-3: Special requirements for electric irons IEC 60335-2-3: 2012 (Replaced) |
2016/08/07 |
CENELEC |
EN 60335-2-4: 2010 Household and similar electrical appliances - Safety - Part 2-4: Special requirements for crimping presses IEC 60335-2-4: 2008 (Changed) |
2016/08/07 |
|
EN 60335-2-4: 2010 / A1: 2015 IEC 60335-2-4: 2008 / A1: 2012 (Changed) |
2016/08/07 |
CENELEC |
EN 60335-2-5: 2015 Household and similar electrical appliances - Safety - Part 2-5: Special requirements for dishwashers IEC 60335-2-5: 2012 (Replaced) |
2016/08/07 |
CENELEC |
EN 60335-2-6: 2015 Household and similar electrical appliances - Safety - Part 2-6: Special requirements for fixed cooking ranges, ovens, ovens and similar appliances IEC 60335-2-6: 2014 (Changed) |
2016/08/07 |
CENELEC |
EN 60335-2-7: 2010 Household and similar electrical appliances - Safety - Part 2-7: Special requirements for washing machines IEC 60335-2-7: 2008 (Changed) |
2016/08/07 |
|
EN 60335-2-7: 2010 / A1: 2013 IEC 60335-2-7: 2008 / A1: 2011 (Changed) |
|
|
EN 60335-2-7: 2010 / A11: 2013 |
2016/08/07 |
CENELEC |
EN 60335-2-8: 2015 Household and similar electrical appliances - Safety - Part 2-8: Special requirements for shavers, hair clippers and similar appliances IEC 60335-2-8: 2012 (Changed) |
2016/08/07 |
|
EN 60335-2-8: 2015 / A1: 2016 IEC 60335-2-8: 2012 / A1: 2015 |
2016/08/07 |
CENELEC |
EN 60335-2-9: 2003 Household and similar electrical appliances - Safety - Part 2-9: Special requirements for grills, toasters and similar portable cooking appliances IEC 60335-2-9: 2002 (Replaced) |
2017/09/08 |
|
EN 60335-2-9: 2003 / A1: 2004 IEC 60335-2-9: 2002 / A1: 2004 |
|
|
EN 60335-2-9: 2003 / A2: 2006 IEC 60335-2-9: 2002 / A2: 2006 |
|
|
EN 60335-2-9: 2003 / A12: 2007 |
|
|
EN 60335-2-9: 2003 / A13: 2010 |
2017/09/08 |
|
EN 60335-2-9: 2003 / A13 |
|
|
EN 60335-2-9: 2003 / A13 |
|
CENELEC |
EN 60335-2-10: 2003 Household and similar electrical appliances - Safety - Part 2-10: Special requirements for tillage machines and wet scrubbing machines IEC 60335-2-10: 2002 |
2016/08/07 |
|
EN 60335-2-10: 2003 / A1: 2008 IEC 60335-2-10: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-11: 2010 Household and similar electrical appliances - Safety - Part 2-11: Special requirements for tumble dryers IEC 60335-2-11: 2008 (Changed) |
2016/08/07 |
|
EN 60335-2-11: 2010 / A1: 2015 IEC 60335-2-11: 2008 / A1: 2012 (Changed) |
2016/08/07 |
|
EN 60335-2-11: 2010 / A11: 2012 |
2016/08/07 |
CENELEC |
EN 60335-2-12: 2003 Household and similar electrical appliances - Safety - Part 2-12: Special requirements for heating plates and similar devices IEC 60335-2-12: 2002 |
2016/08/07 |
|
EN 60335-2-12: 2003 / A1: 2008 IEC 60335-2-12: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-13: 2010 Household and similar electrical appliances - Safety - Part 2-13: Special requirements for deep-fat fryers, frying pans and similar appliances IEC 60335-2-13: 2009 |
2016/08/07 |
|
EN 60335-2-13: 2010 / A11: 2012 |
2016/08/07 |
CENELEC |
EN 60335-2-15: 2002 Household and similar electrical appliances - Safety - Part 2-15: Special requirements for devices used to heat liquids IEC 60335-2-15: 2002 |
2016/08/07 |
|
EN 60335-2-15: 2002 / A1: 2005 IEC 60335-2-15: 2002 / A1: 2005 |
|
|
EN 60335-2-15: 2002 / A2: 2008 IEC 60335-2-15: 2002 / A2: 2008 |
|
|
EN 60335-2-15: 2002 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-15: 2002 / A11 |
|
|
EN 60335-2-15: 2002 / AC: 2005 |
|
|
EN 60335-2-15: 2002 / AC: 2006 |
|
CENELEC |
EN 60335-2-16: 2003 Household and similar electrical appliances - Safety - Part 2-16: Special requirements for food waste IEC 60335-2-16: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-16: 2003 / A1: 2008 IEC 60335-2-16: 2002 / A1: 2008 |
|
|
EN 60335-2-16: 2003 / A2: 2012 IEC 60335-2-16: 2002 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-17: 2013 Household and similar electrical appliances - Safety - Part 2-17: Special requirements for blankets, pads, garments and similar flexible heating devices IEC 60335-2-17: 2012 |
2016/08/07 |
CENELEC |
EN 60335-2-21: 2003 Household and similar electrical appliances - Safety - Part 2-21: Special requirements for storage water heaters IEC 60335-2-21: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-21: 2003 / A1: 2005 IEC 60335-2-21: 2002 / A1: 2004 |
|
|
EN 60335-2-21: 2003 / A2: 2008 IEC 60335-2-21: 2002 / A2: 2008 |
2016/08/07 |
|
EN 60335-2-21: 2003 / AC: 2007 |
|
|
EN 60335-2-21: 2003 / AC: 2010 |
|
CENELEC |
EN 60335-2-23: 2003 Household and similar electrical appliances - Safety - Part 2-23: Specific requirements for devices for skin or hair care IEC 60335-2-23: 2003 |
2016/08/07 |
|
EN 60335-2-23: 2003 / A1: 2008 IEC 60335-2-23: 2003 / A1: 2008 |
|
|
EN 60335-2-23: 2003 / A2: 2015 IEC 60335-2-23: 2003 / A2: 2012 (Changed) |
2016/08/07 |
|
EN 60335-2-23: 2003 / A11: 2010 |
2016/08/07 |
|
EN 60335-2-23: 2003 / A11 |
|
CENELEC |
EN 60335-2-25: 2012 Household and similar electrical appliances - Safety - Part 2-25: Special requirements for microwave ovens, including combinations of microwave ovens IEC 60335-2-25: 2010 (Changed) |
2016/08/07 |
|
EN 60335-2-25: 2012 / A1: 2015 IEC 60335-2-25: 2010 / A1: 2014 |
2016/08/07 |
|
EN 60335-2-25: 2012 / A2: 2016 IEC 60335-2-25: 2010 / A2: 2015 |
2016/08/07 |
CENELEC |
EN 60335-2-26: 2003 Household and similar electrical appliances - Safety - Part 2-26: Special requirements for watches IEC 60335-2-26: 2002 |
2016/08/07 |
|
EN 60335-2-26: 2003 / A1: 2008 IEC 60335-2-26: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-27: 2013 Household and similar electrical appliances - Safety - Part 2-27: Special requirements for devices exposed to ultraviolet and infrared radiation exposure IEC 60335-2-27: 2009 (Changed) |
2016/08/07 |
CENELEC |
EN 60335-2-28: 2003 Household and similar electrical appliances - Safety - Part 2-28: Special requirements for sewing machines IEC 60335-2-28: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-28: 2003 / A1: 2008 IEC 60335-2-28: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-29: 2004 Household and similar electrical appliances - Safety - Part 2-29: Special requirements for battery chargers IEC 60335-2-29: 2002 + A1: 2004 |
2016/08/07 |
|
EN 60335-2-29: 2004 / A2: 2010 IEC 60335-2-29: 2002 / A2: 2009 |
2016/08/07 |
CENELEC |
EN 60335-2-30: 2009 Household and similar electrical appliances - Safety - Part 2-30: Special requirements for room heaters IEC 60335-2-30: 2009 |
2016/08/07 |
|
EN 60335-2-30: 2009 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-30: 2009 / AC: 2010 |
|
|
EN 60335-2-30: 2009 / AC: 2014 |
|
CENELEC |
EN 60335-2-31: 2014 Household and similar electrical appliances - Safety - Part 2-31: Special requirements for range hoods and other cooking fume extractors IEC 60335-2-31: 2012 (Replaced) |
2016/08/07 |
CENELEC |
EN 60335-2-32: 2003 Household and similar electrical appliances - Safety - Part 2-32: Special requirements for massage devices IEC 60335-2-32: 2002 |
2016/08/07 |
|
EN 60335-2-32: 2003 / A1: 2008 IEC 60335-2-32: 2002 / A1: 2008 |
|
|
EN 60335-2-32: 2003 / A2: 2015 IEC 60335-2-32: 2002 / A2: 2013 (Changed) |
2016/08/07 |
CENELEC |
EN 60335-2-34: 2013 Household and similar electrical appliances - Safety - Part 2-34: Special requirements for motor compressors IEC 60335-2-34: 2012 |
2016/08/07 |
CENELEC |
EN 60335-2-35: 2016 Household and similar electrical appliances - Safety - Part 2-35: Special requirements for instantaneous water heaters IEC 60335-2-35: 2012 (Replaced) |
2016/08/07 |
CENELEC |
EN 60335-2-36: 2002 Household and similar electrical appliances - Safety - Part 2-36: Special requirements for commercial electric cookers, ovens, stoves and cooking elements IEC 60335-2-36: 2002 |
2016/08/07 |
|
EN 60335-2-36: 2002 / A1: 2004 IEC 60335-2-36: 2002 / A1: 2004 |
|
|
EN 60335-2-36: 2002 / A2: 2008 IEC 60335-2-36: 2002 / A2: 2008 |
|
|
EN 60335-2-36: 2002 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-36: 2002 / AC: 2007 |
|
CENELEC |
EN 60335-2-37: 2002 Household and similar electrical appliances - Safety - Part 2-37: Special requirements for commercial electric deep-fat fryers IEC 60335-2-37: 2002 |
2016/08/07 |
|
EN 60335-2-37: 2002 / A1: 2008 IEC 60335-2-37: 2002 / A1: 2008 |
|
|
EN 60335-2-37: 2002 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-37: 2002 / AC: 2007 |
|
CENELEC |
EN 60335-2-38: 2003 Household and similar electrical appliances - Safety - Part 2-38: Special requirements for commercial electric grills and griddle grills IEC 60335-2-38: 2002 |
2016/08/07 |
|
EN 60335-2-38: 2003 / A1: 2008 IEC 60335-2-38: 2002 / A1: 2008 |
2016/08/07 |
|
EN 60335-2-38: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-39: 2003 Household and similar electrical appliances - Safety - Part 2-39: Special requirements for commercial electric multi-purpose cooking pans IEC 60335-2-39: 2002 |
2016/08/07 |
|
EN 60335-2-39: 2003 / A1: 2004 IEC 60335-2-39: 2002 / A1: 2004 |
|
|
EN 60335-2-39: 2003 / A2: 2008 IEC 60335-2-39: 2002 / A2: 2008 |
2016/08/07 |
|
EN 60335-2-39: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-40: 2003 Household and similar electrical appliances - Safety - Part 2-40: Special requirements for electrical heat pumps, air conditioners and dehumidifiers IEC 60335-2-40: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-40: 2003 / A1: 2006 IEC 60335-2-40: 2002 / A1: 2005 (Changed) |
|
|
EN 60335-2-40: 2003 / A2: 2009 IEC 60335-2-40: 2002 / A2: 2005 (Changed) |
|
|
EN 60335-2-40: 2003 / A11: 2004 |
|
|
EN 60335-2-40: 2003 / A12: 2005 |
|
|
EN 60335-2-40: 2003 / A13: 2012 |
2016/08/07 |
|
EN 60335-2-40: 2003 / A13 |
|
|
EN 60335-2-40: 2003 / AC: 2006 |
|
|
EN 60335-2-40: 2003 / AC: 2010 |
|
CENELEC |
EN 60335-2-41: 2003 Household and similar electrical appliances - Safety - Part 2-41: Special requirements for pumps IEC 60335-2-41: 2002 |
2016/08/07 |
|
EN 60335-2-41: 2003 / A1: 2004 IEC 60335-2-41: 2002 / A1: 2004 |
|
|
EN 60335-2-41: 2003 / A2: 2010 IEC 60335-2-41: 2002 / A2: 2009 |
2016/08/07 |
CENELEC |
EN 60335-2-42: 2003 Household and similar electrical appliances - Safety - Part 2-42: Special requirements for commercial electric forced convection ovens, steam cookers and steam convection ovens IEC 60335-2-42: 2002 |
2016/08/07 |
|
EN 60335-2-42: 2003 / A1: 2008 IEC 60335-2-42: 2002 / A1: 2008 |
|
|
EN 60335-2-42: 2003 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-42: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-43: 2003 Household and similar electrical appliances - Safety - Part 2-43: Special requirements for clothes dryers and towel rails IEC 60335-2-43: 2002 |
2016/08/07 |
|
EN 60335-2-43: 2003 / A1: 2006 IEC 60335-2-43: 2002 / A1: 2005 |
|
|
EN 60335-2-43: 2003 / A2: 2008 IEC 60335-2-43: 2002 / A2: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-44: 2002 Household and similar electrical appliances - Safety - Part 2-44: Special requirements for blacksmiths IEC 60335-2-44: 2002 |
2016/08/07 |
|
EN 60335-2-44: 2002 / A1: 2008 IEC 60335-2-44: 2002 / A1: 2008 |
|
|
EN 60335-2-44: 2002 / A2: 2012 IEC 60335-2-44: 2002 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-45: 2002 Household and similar electrical appliances - Safety - Part 2-45: Special requirements for portable heating appliances and similar appliances IEC 60335-2-45: 2002 |
2016/08/07 |
|
EN 60335-2-45: 2002 / A1: 2008 IEC 60335-2-45: 2002 / A1: 2008 |
|
|
EN 60335-2-45: 2002 / A2: 2012 IEC 60335-2-45: 2002 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-47: 2003 Household and similar electrical appliances - Safety - Part 2-47: Special requirements for commercial electric boiling pan IEC 60335-2-47: 2002 |
2016/08/07 |
|
EN 60335-2-47: 2003 / A1: 2008 IEC 60335-2-47: 2002 / A1: 2008 |
|
|
EN 60335-2-47: 2003 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-47: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-48: 2003 Household and similar electrical appliances - Safety - Part 2-48: Special requirements for commercial electric grills and toasters IEC 60335-2-48: 2002 |
2016/08/07 |
|
EN 60335-2-48: 2003 / A1: 2008 IEC 60335-2-48: 2002 / A1: 2008 |
|
|
EN 60335-2-48: 2003 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-48: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-49: 2003 Household and similar electrical appliances - Safety - Part 2-49: Special requirements for commercial electrical appliances to maintain food and plate temperature IEC 60335-2-49: 2002 |
2016/08/07 |
|
EN 60335-2-49: 2003 / A1: 2008 IEC 60335-2-49: 2002 / A1: 2008 |
|
|
EN 60335-2-49: 2003 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-49: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-50: 2003 Household and similar electrical appliances - Safety - Part 2-50: Special requirements for commercial electric bains-marie IEC 60335-2-50: 2002 |
2016/08/07 |
|
EN 60335-2-50: 2003 / A1: 2008 IEC 60335-2-50: 2002 / A1: 2007 |
2016/08/07 |
|
EN 60335-2-50: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-51: 2003 Household and similar electrical appliances - Safety - Part 2-51: Special requirements for stationary circulation pumps for heating and service plumbing IEC 60335-2-51: 2002 |
2016/08/07 |
|
EN 60335-2-51: 2003 / A1: 2008 IEC 60335-2-51: 2002 / A1: 2008 |
|
|
EN 60335-2-51: 2003 / A2: 2012 IEC 60335-2-51: 2002 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-52: 2003 Household and similar electrical appliances - Safety - Part 2-52: Special requirements for oral hygiene devices IEC 60335-2-52: 2002 |
2016/08/07 |
|
EN 60335-2-52: 2003 / A1: 2008 IEC 60335-2-52: 2002 / A1: 2008 |
|
|
EN 60335-2-52: 2003 / A11: 2010 |
2016/08/07 |
|
EN 60335-2-52: 2003 / A11 |
|
CENELEC |
EN 60335-2-53: 2011 Household and similar electrical appliances - Safety - Part 2-53: Special requirements for sauna heaters and infrared cabins IEC 60335-2-53: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-54: 2008 Household and similar electrical appliances - Safety - Part 2-54: Special requirements for surface cleaning devices that use liquid or steam for domestic use IEC 60335-2-54: 2008 |
2016/08/07 |
|
EN 60335-2-54: 2008 / A1: 2015 IEC 60335-2-54: 2008 / A1: 2015 |
2016/08/07 |
|
EN 60335-2-54: 2008 / A11: 2012 |
2016/08/07 |
|
EN 60335-2-54: 2008 / A11 |
|
CENELEC |
EN 60335-2-55: 2003 Household and similar electrical appliances - Safety - Part 2-55: Special requirements for electrical appliances for use with aquariums and garden ponds IEC 60335-2-55: 2002 |
2016/08/07 |
|
EN 60335-2-55: 2003 / A1: 2008 IEC 60335-2-55: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-56: 2003 Household and similar electrical appliances - Safety - Part 2-56: Special requirements for projectors and similar devices IEC 60335-2-56: 2002 |
2016/08/07 |
|
EN 60335-2-56: 2003 / A1: 2008 IEC 60335-2-56: 2002 / A1: 2008 |
|
|
EN 60335-2-56: 2003 / A2: 2014 IEC 60335-2-56: 2002 / A2: 2014 |
2016/08/07 |
CENELEC |
EN 60335-2-58: 2005 Household and similar electrical appliances - Safety - Part 2-58: Special requirements for commercial electric dishwashers IEC 60335-2-58: 2002 (Replaced) |
2016/08/07 |
CENELEC |
EN 60335-2-59: 2003 Household and similar electrical appliances - Safety - Part 2-59: Special requirements for insecticides IEC 60335-2-59: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-59: 2003 / A1: 2006 IEC 60335-2-59: 2002 / A1: 2006 |
|
|
EN 60335-2-59: 2003 / A2: 2009 IEC 60335-2-59: 2002 / A2: 2009 |
2016/08/07 |
CENELEC |
EN 60335-2-60: 2003 Household and similar electrical appliances - Safety - Part 2-60: Special requirements for whirlpool baths and whirlpool spas IEC 60335-2-60: 2002 |
2016/08/07 |
|
EN 60335-2-60: 2003 / A1: 2005 IEC 60335-2-60: 2002 / A1: 2004 |
|
|
EN 60335-2-60: 2003 / A2: 2008 IEC 60335-2-60: 2002 / A2: 2008 |
|
|
EN 60335-2-60: 2003 / A11: 2010 |
|
|
EN 60335-2-60: 2003 / A12: 2010 |
2016/08/07 |
CENELEC |
EN 60335-2-61: 2003 Household and similar electrical appliances - Safety - Part 2-61: Special requirements for thermal storage room heaters IEC 60335-2-61: 2002 |
2016/08/07 |
|
EN 60335-2-61: 2003 / A1: 2005 IEC 60335-2-61: 2002 / A1: 2005 |
|
|
EN 60335-2-61: 2003 / A2: 2008 IEC 60335-2-61: 2002 / A2: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-62: 2003 Household and similar electrical appliances - Safety - Part 2-62: Special requirements for commercial electric rinsing sinks IEC 60335-2-62: 2002 |
2016/08/07 |
|
EN 60335-2-62: 2003 / A1: 2008 IEC 60335-2-62: 2002 / A1: 2008 |
2016/08/07 |
|
EN 60335-2-62: 2003 / AC: 2007 |
|
CENELEC |
EN 60335-2-65: 2003 Household and similar electrical appliances - Safety - Part 2-65: Special requirements for air purification devices IEC 60335-2-65: 2002 |
2016/08/07 |
|
EN 60335-2-65: 2003 / A1: 2008 IEC 60335-2-65: 2002 / A1: 2008 |
|
|
EN 60335-2-65: 2003 / A11: 2012 |
2016/08/07 |
CENELEC |
EN 60335-2-66: 2003 Household and similar electrical appliances - Safety - Part 2-66: Special requirements for water bed heaters IEC 60335-2-66: 2002 |
2016/08/07 |
|
EN 60335-2-66: 2003 / A1: 2008 IEC 60335-2-66: 2002 / A1: 2008 |
|
|
EN 60335-2-66: 2003 / A2: 2012 IEC 60335-2-66: 2002 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-70: 2002 Household and similar electrical appliances - Safety - Part 2-70: Special requirements for milking machines IEC 60335-2-70: 2002 |
2016/08/07 |
CENELEC |
EN 60335-2-71: 2003 Household and similar electrical appliances - Safety - Part 2-71: Special requirements for electrical heating devices for the breeding and rearing of animals IEC 60335-2-71: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-71: 2003 / A1: 2007 IEC 60335-2-71: 2002 / A1: 2007 |
2016/08/07 |
CENELEC |
EN 60335-2-73: 2003 Household and similar electrical appliances - Safety - Part 2-73: Special requirements for fixed immersion heaters IEC 60335-2-73: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-73: 2003 / A1: 2006 IEC 60335-2-73: 2002 / A1: 2006 |
|
|
EN 60335-2-73: 2003 / A2: 2009 IEC 60335-2-73: 2002 / A2: 2009 |
2016/08/07 |
CENELEC |
EN 60335-2-74: 2003 Household and similar electrical appliances - Safety - Part 2-74: Special requirements for portable immersion heaters IEC 60335-2-74: 2002 |
2016/08/07 |
|
EN 60335-2-74: 2003 / A1: 2006 IEC 60335-2-74: 2002 / A1: 2006 |
|
|
EN 60335-2-74: 2003 / A2: 2009 IEC 60335-2-74: 2002 / A2: 2009 |
2016/08/07 |
CENELEC |
EN 60335-2-75: 2004 Household and similar electrical appliances - Safety - Part 2-75: Special requirements for commercial distribution devices and vending machines IEC 60335-2-75: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-75: 2004 / A1: 2005 IEC 60335-2-75: 2002 / A1: 2004 |
|
|
EN 60335-2-75: 2004 / A2: 2008 IEC 60335-2-75: 2002 / A2: 2008 |
|
|
EN 60335-2-75: 2004 / A11: 2006 |
|
|
EN 60335-2-75: 2004 / A12: 2010 |
2016/08/07 |
CENELEC |
EN 60335-2-78: 2003 Household and similar electrical appliances - Safety - Part 2-78: Special requirements for outdoor barbecues IEC 60335-2-78: 2002 |
2016/08/07 |
|
EN 60335-2-78: 2003 / A1: 2008 IEC 60335-2-78: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-80: 2003 + 6Household applications and similar electrical appliances - Safety - Part 2-80: Special requirements for fans IEC 60335-2-80: 2002 |
2016/08/07 |
|
EN 60335-2-80: 2003 / A1: 2004 IEC 60335-2-80: 2002 / A1: 2004 |
|
|
EN 60335-2-80: 2003 / A2: 2009 IEC 60335-2-80: 2002 / A2: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-81: 2003 Household and similar electrical appliances - Safety - Part 2-81: Special requirements for foot heaters and heating mats IEC 60335-2-81: 2002 |
2016/08/07 |
|
EN 60335-2-81: 2003 / A1: 2007 IEC 60335-2-81: 2002 / A1: 2007 |
|
|
EN 60335-2-81: 2003 / A2: 2012 IEC 60335-2-81: 2002 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60335-2-82: 2003 Household and similar electrical appliances - Safety - Part 2-82: Special requirements for amusement machines and personal service machines IEC 60335-2-82: 2002 |
2016/08/07 |
|
EN 60335-2-82: 2003 / A1: 2008 IEC 60335-2-82: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-83: 2002 Household and similar electrical appliances - Safety - Part 2-83: Special requirements for heated gullies for roof drainage IEC 60335-2-83: 2001 |
2016/08/07 |
|
EN 60335-2-83: 2002 / A1: 2008 IEC 60335-2-83: 2001 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-84: 2003 Household and similar electrical appliances - Safety - Part 2-84: Special requirements for toilets IEC 60335-2-84: 2002 |
2016/08/07 |
|
EN 60335-2-84: 2003 / A1: 2008 IEC 60335-2-84: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-85: 2003 Household and similar electrical appliances - Safety - Part 2-85: Special requirements for fabric steamers IEC 60335-2-85: 2002 |
2016/08/07 |
|
EN 60335-2-85: 2003 / A1: 2008 IEC 60335-2-85: 2002 / A1: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-86: 2003 Household and similar electrical appliances - Safety - Part 2-86: Special requirements for electrical fishing machines IEC 60335-2-86: 2002 (Replaced) |
2016/08/07 |
|
EN 60335-2-86: 2003 / A1: 2005 IEC 60335-2-86: 2002 / A1: 2005 |
|
|
EN 60335-2-86: 2003 / A2: 2016 IEC 60335-2-86: 2002 / A2: 2012 |
2016/08/07 |
|
EN 60335-2-86: 2003 / A11: 2016 |
2016/08/07 |
CENELEC |
EN 60335-2-87: 2002 Household and similar electrical appliances - Safety - Part 2-87: Special requirements of electrical animal equipment IEC 60335-2-87: 2002 |
2016/08/07 |
|
EN 60335-2-87: 2002 / A1: 2007 IEC 60335-2-87: 2002 / A1: 2007 |
2016/08/07 |
CENELEC |
EN 60335-2-88: 2002 Household and similar electrical appliances - Safety - Part 2-88: Special requirements for humidifiers designed for use with heating, ventilation or air-conditioning systems IEC 60335-2-88: 2002 |
2016/08/07 |
CENELEC |
EN 60335-2-90: 2006 Household and similar electrical appliances - Safety - Part 2-90: Special requirements for commercial microwave ovens IEC 60335-2-90: 2006 |
2016/08/07 |
|
EN 60335-2-90: 2006 / A1: 2010 IEC 60335-2-90: 2006 / A1: 2010 |
2016/08/07 |
CENELEC |
EN 60335-2-96: 2002 Household and similar electrical appliances - Safety - Part 2-96: Special requirements for flexible sheet heating elements for room heating IEC 60335-2-96: 2002 |
2016/08/07 |
|
EN 60335-2-96: 2002 / A1: 2004 IEC 60335-2-96: 2002 / A1: 2003 |
|
|
EN 60335-2-96: 2002 / A2: 2009 IEC 60335-2-96: 2002 / A2: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-97: 2006 Household and similar electrical appliances - Safety - Part 2-97: Special requirements for drives for shutters, awnings, shutters and similar equipment IEC 60335-2-97: 2002 (Changed) + A1: 2004 (Changed) |
2016/08/07 |
|
EN 60335-2-97: 2006 / A2: 2010 IEC 60335-2-97: 2002 / A2: 2008 (Changed) |
|
|
EN 60335-2-97: 2006 / A11: 2008 |
|
|
EN 60335-2-97: 2006 / A12: 2015 |
2016/08/07 |
CENELEC |
EN 60335-2-98: 2003 Household and similar electrical appliances - Safety - Part 2-98: Special requirements for humidifiers IEC 60335-2-98: 2002 |
2016/08/07 |
|
EN 60335-2-98: 2003 / A1: 2005 IEC 60335-2-98: 2002 / A1: 2004 |
|
|
EN 60335-2-98: 2003 / A2: 2008 IEC 60335-2-98: 2002 / A2: 2008 |
2016/08/07 |
CENELEC |
EN 60335-2-99: 2003 Household and similar electrical appliances - Safety - Part 2-99: Special requirements for commercial electric hoods IEC 60335-2-99: 2003 |
2016/08/07 |
CENELEC |
EN 60335-2-101: 2002 Household and similar electrical appliances - Safety - Part 2-101: Special requirements for evaporators IEC 60335-2-101: 2002 |
2016/08/07 |
|
EN 60335-2-101: 2002 / A1: 2008 IEC 60335-2-101: 2002 / A1: 2008 |
|
|
EN 60335-2-101: 2002 / A2: 2014 IEC 60335-2-101: 2002 / A2: 2014 |
2016/08/07 |
CENELEC |
EN 60335-2-102: 2016 Household and similar electrical appliances - Safety - Part 2-102: Special requirements for gas, oil and solid fuel combustion devices with electrical connections IEC 60335-2-102: 2004 (Replaced) IEC 60335-2-102: 2004 / A1: 2008 (Changed) + A1: 2008 (Changed) IEC 60335-2-102: 2004 / A2: 2012 (Changed) |
2016/08/07 |
CENELEC |
EN 60335-2-105: 2005 Household and similar electrical appliances - Safety - Part 2-105: Special requirements for multi-function shower enclosures IEC 60335-2-105: 2004 |
2016/08/07 |
|
EN 60335-2-105: 2005 / A1: 2008 IEC 60335-2-105: 2004 / A1: 2008 |
|
|
EN 60335-2-105: 2005 / A11: 2010 |
2016/08/07 |
CENELEC |
EN 60335-2-106: 2007 Domestic and similar electrical appliances - Safety - Part 2-106: Special requirements for heated carpets and heating units for room heating installed under removable floor coverings IEC 60335-2-106: 2007 |
2016/08/07 |
CENELEC |
EN 60335-2-108: 2008 Household and similar electrical appliances - Safety - Part 2-108: Special requirements for electrolysers IEC 60335-2-108: 2008 (Changed) |
2016/08/07 |
CENELEC |
EN 60335-2-109: 2010 Household and similar electrical appliances - Safety - Part 2-109: Special requirements for UV radiation treatment devices IEC 60335-2-109: 2010 |
2016/08/07 |
CENELEC |
IN 60358-1: 2012 Coupling capacitors and capacitor dividers - Part 1: General rules IEC 60358-1: 2012 |
2016/08/07 |
|
EN 60358-1: 2012 / AC: 2013 |
|
CENELEC |
AND 60360: 1998 Lamp cover temperature rise standard measurement method IEC 60360: 1998 |
2016/08/07 |
CENELEC |
AND 60399: 2004 Barrel thread for shade holder ring shades IEC 60399: 2004 |
2016/08/07 |
|
EN 60399: 2004 / A1: 2008 IEC 60399: 2004 / A1: 2008 |
2016/08/07 |
CENELEC |
AND 60400: 2008 Fluorescent tubes and lamps for starter holders IEC 60400: 2008 |
2016/08/07 |
|
EN 60400: 2008 / A1: 2011 IEC 60400: 2008 / A1: 2011 |
|
|
EN 60400: 2008 / A2: 2014 IEC 60400: 2008 / A2: 2014 |
2016/08/07 |
CENELEC |
AND 60423: 2007 Cable systems for cable management - External diameters of ducts for electrical installations and threads for pipes and fittings IEC 60423: 2007 |
2016/08/07 |
CENELEC |
IN 60432-1: 2000 Incandescent lamps - Safety features - Part 1: Tungsten filament lamps for household and similar general lighting purposes IEC 60432-1: 1999 (Replaced) |
2016/08/07 |
|
EN 60432-1: 2000 / A1: 2005 IEC 60432-1: 1999 / A1: 2005 |
|
|
EN 60432-1: 2000 / A2: 2012 IEC 60432-1: 1999 / A2: 2011 |
2016/08/07 |
CENELEC |
IN 60432-2: 2000 Incandescent lamps - Safety features - Part 2: Tungsten halogen lamps for domestic and similar general lighting IEC 60432-2: 1999 (Replaced) |
2016/08/07 |
|
EN 60432-2: 2000 / A1: 2005 IEC 60432-2: 1999 / A1: 2005 (Replaced) |
|
|
EN 60432-2: 2000 / A2: 2012 IEC 60432-2: 1999 / A2: 2012 |
2016/08/07 |
CENELEC |
IN 60432-3: 2013 Incandescent lamps - Safety features - Part 3: Tungsten halogen lamps (without tools) IEC 60432-3: 2012 |
2016/08/07 |
CENELEC |
AND 60477: 1997 Laboratory dc resistors IEC 60477: 1974 |
2016/08/07 |
|
EN 60477: 1997 / A1: 1997 IEC 60477: 1974 / A1: 1997 |
2016/08/07 |
CENELEC |
IN 60477-2: 1997 Laboratory resistors - Part 2: Laboratory ac resistors IEC 60477-2: 1979 |
2016/08/07 |
|
EN 60477-2: 1997 / A1: 1997 IEC 60477-2: 1979 / A1: 1997 |
2016/08/07 |
CENELEC |
IN 60519-1: 2015 Safety in installations for electro-heating and electromagnetic processing - Part 1: General requirements IEC 60519-1: 2015 |
2016/08/07 |
CENELEC |
IN 60519-2: 2006 Safety in electric heaters - Part 2: Special requirements for resistance heating equipment IEC 60519-2: 2006 |
2016/08/07 |
CENELEC |
IN 60519-3: 2005 Safety in electric heating plants - Part 3: Special requirements for induction and conduction heating and induction melting installations IEC 60519-3: 2005 |
2016/08/07 |
CENELEC |
IN 60519-4: 2013 Safety in electric heating installations - Part 4: Particular requirements for arc furnace installations IEC 60519-4: 2013 |
2016/08/07 |
CENELEC |
IN 60519-6: 2011 Safety in electric heating plants - Part 6: Safety features in industrial microwave heating equipment IEC 60519-6: 2011 |
2016/08/07 |
CENELEC |
IN 60519-7: 2008 Safety in electric heating installations - Part 7: Special requirements for installations with electron guns IEC 60519-7: 2008 |
2016/08/07 |
CENELEC |
IN 60519-8: 2005 Safety in electric heating plants - Part 8: Particular requirements for electroslag reelting furnaces IEC 60519-8: 2005 |
2016/08/07 |
CENELEC |
IN 60519-9: 2005 Safety in electrical installation installations - Part 9: Special requirements for high frequency dielectric heating installations IEC 60519-9: 2005 |
2016/08/07 |
CENELEC |
IN 60519-10: 2013 Safety in electrical heating installations - Part 10: Particular requirements for electrically resistant trace heating systems for industrial and commercial applications IEC 60519-10: 2013 |
2016/08/07 |
CENELEC |
IN 60519-12: 2013 Safety in electric heating installations - Part 12: Special requirements for infrared electric heating installations IEC 60519-12: 2013 |
2016/08/07 |
CENELEC |
IN 60519-21: 2009 Safety in electric heaters - Part 21: Particular requirements for resistance heating equipment - Heater and melting glass equipment IEC 60519-21: 2008 |
2016/08/07 |
CENELEC |
AND 60523: 1993 Direct current potentiometers IEC 60523: 1975 + A1: 1979 |
2016/08/07 |
|
EN 60523: 1993 / A2: 1997 IEC 60523: 1975 / A2: 1997 |
2016/08/07 |
CENELEC |
AND 60524: 1993 Direct current resistance volt rate boxes IEC 60524: 1975 + A1: 1981 |
2016/08/07 |
|
EN 60524: 1993 / A2: 1997 IEC 60524: 1975 / A2: 1997 |
2016/08/07 |
CENELEC |
AND 60529: 1991 Degree of protection provided by enclosures (IP Code) IEC 60529: 1989 |
2016/08/07 |
|
EN 60529: 1991 / A1: 2000 IEC 60529: 1989 / A1: 1999 |
|
|
EN 60529: 1991 / A2: 2013 IEC 60529: 1989 / A2: 2013 |
2016/08/07 |
|
EN 60529: 1991 / AC: 1993 |
|
CENELEC |
AND 60564: 1993 DC bridges for resistance measurement IEC 60564: 1977 + A1: 1981 |
2016/08/07 |
|
EN 60564: 1993 / A2: 1997 IEC 60564: 1977 / A2: 1997 |
2016/08/07 |
CENELEC |
AND 60570: 2003 Electric supply rail systems for fittings IEC 60570: 2003 (Replaced) |
2016/08/07 |
CENELEC |
IN 60598-1: 2015 Fixtures - Part 1: General requirements and tests IEC 60598-1: 2014 (Changed) |
2016/08/07 |
|
EN 60598-1: 2015 / AC: 2015 |
|
|
EN 60598-1: 2015 / AC: 2016 |
|
CENELEC |
EN 60598-2-1: 1989 Luminaires - Part 2: Special Conditions - Part 1: Fixed General Purpose Luminaires IEC 60598-2-1: 1979 + A1: 1987 |
2016/08/07 |
CENELEC |
EN 60598-2-2: 2012 Luminaires - Part 2-2: Special Requirements - Recessed Luminaires IEC 60598-2-2: 2011 |
2016/08/07 |
CENELEC |
EN 60598-2-3: 2003 Fixtures - Part 2-3: Special requirements - Fixtures for road and street lighting IEC 60598-2-3: 2002 |
2016/08/07 |
|
EN 60598-2-3: 2003 / A1: 2011 IEC 60598-2-3: 2002 / A1: 2011 |
2016/08/07 |
|
EN 60598-2-3: 2003 / AC: 2005 |
|
CENELEC |
EN 60598-2-4: 1997 Luminaires - Part 2: Special Conditions - Part 4: Portable general purpose luminaires IEC 60598-2-4: 1997 |
2016/08/07 |
CENELEC |
EN 60598-2-5: 2015 Luminaires - Part 2-5: Special Requirements - Projectors IEC 60598-2-5: 2015 |
2016/08/07 |
CENELEC |
EN 60598-2-7: 1989 Luminaires - Part 2: Special Conditions - Part 7: Portable luminaires for garden use IEC 60598-2-7: 1982 (Changed) + A1: 1987 (Changed) |
2016/08/07 |
|
EN 60598-2-7: 1989 / A2: 1996 IEC 60598-2-7: 1982 / A2: 1994 (Changed) |
|
|
EN 60598-2-7: 1989 / A13: 1997 |
2016/08/07 |
|
EN 60598-2-7: 1989 / A2 |
|
CENELEC |
EN 60598-2-8: 2013 Luminaires - Part 2-8: Special Requirements - Handlamps IEC 60598-2-8: 2013 |
2016/08/07 |
CENELEC |
EN 60598-2-9: 1989 Fixtures - Part 2: Special Conditions - Part 9: Photo and film fixtures (non-professional) IEC 60598-2-9: 1987 |
2016/08/07 |
|
EN 60598-2-9: 1989 / A1: 1994 IEC 60598-2-9: 1987 / A1: 1993 |
2016/08/07 |
CENELEC |
EN 60598-2-10: 2003 Luminaires - Part 2-10: Special requirements - Portable luminaires for children IEC 60598-2-10: 2003 |
2016/08/07 |
|
EN 60598-2-10: 2003 / AC: 2005 |
|
CENELEC |
EN 60598-2-11: 2013 Luminaires - Part 2-11: Special Conditions - Aquarium Luminaires IEC 60598-2-11: 2013 |
2016/08/07 |
CENELEC |
EN 60598-2-12: 2013 Luminaires - Part 2-12: Special requirements - Mains socket-mounted IEC 60598-2-12: 2013 |
2016/08/07 |
CENELEC |
EN 60598-2-13: 2006 Luminaires - Part 2-13: Special Conditions - Recessed Luminaires IEC 60598-2-13: 2006 |
2016/08/07 |
|
EN 60598-2-13: 2006 / A1: 2012 IEC 60598-2-13: 2006 / A1: 2011 |
|
|
EN 60598-2-13: 2006 / AC: 2006 |
|
CENELEC |
EN 60598-2-14: 2009 Fixtures - Part 2-14: Special requirements - Fixtures for cold cathode tube discharge lamps (neon tubes) and similar equipment IEC 60598-2-14: 2009 |
2016/08/07 |
CENELEC |
EN 60598-2-17: 1989 Fixtures - Part 2: Special Requirements - Part 17: Fixtures for stage lighting, television film and photo studios (indoor and outdoor) IEC 60598-2-17: 1984 + A1: 1987 |
2016/08/07 |
|
EN 60598-2-17: 1989 / A2: 1991 IEC 60598-2-17: 1984 / A2: 1990 |
2016/08/07 |
CENELEC |
EN 60598-2-19: 1989 Luminaires - Part 2: Special Requirements - Part 19: Air control luminaires (safety requirements) IEC 60598-2-19: 1981 (Changed) + A1: 1987 (Changed) |
2016/08/07 |
|
EN 60598-2-19: 1989 / A2: 1998 IEC 60598-2-19: 1981 / A2: 1997 |
2016/08/07 |
|
EN 60598-2-19: 1989 / AC: 2005 |
|
CENELEC |
EN 60598-2-20: 2015 Luminaires - Part 2-20: Special Requirements - Lighting chains IEC 60598-2-20: 2014 |
2016/08/07 |
CENELEC |
EN 60598-2-21: 2015 Luminaires - Part 2-21: Special Requirements - Rope Lights IEC 60598-2-21: 2014 |
2016/08/07 |
CENELEC |
EN 60598-2-22: 2014 Luminaires - Part 2-22: Special Requirements - Luminaires for emergency lighting IEC 60598-2-22: 2014 |
2016/08/07 |
|
EN 60598-2-22: 2014 / AC: 2015 |
|
CENELEC |
EN 60598-2-23: 1996 Luminaires - Part 2-23: Special Requirements - Extra low voltage lighting systems for filament lamps IEC 60598-2-23: 1996 |
2016/08/07 |
|
EN 60598-2-23: 1996 / A1: 2000 IEC 60598-2-23: 1996 / A1: 2000 |
2016/08/07 |
|
EN 60598-2-23: 1996 / AC: 1997 |
|
CENELEC |
EN 60598-2-24: 2013 Luminaires - Part 2-24: Special Requirements - Luminaires with limited surface temperatures IEC 60598-2-24: 2013 |
2016/08/07 |
CENELEC |
EN 60598-2-25: 1994 Luminaires - Part 2-25: Special Requirements - Luminaires for use in the clinical areas of hospital and healthcare buildings IEC 60598 IEC 60598-2-25: 1994 |
2016/08/07 |
|
EN 60598-2-25: 1994 / A1: 2004 IEC 60598-2-25: 1994 / A1: 2004 |
2016/08/07 |
CENELEC |
AND 60618: 1997 Inductive voltage dividers IEC 60618: 1978 + A1: 1981 |
2016/08/07 |
|
EN 60618: 1997 / A2: 1997 IEC 60618: 1978 / A2: 1997 |
2016/08/07 |
CENELEC |
IN 60645-1: 2015 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure tone audiometry IEC 60645-1: 2012 |
2016/08/07 |
CENELEC |
IN 60645-3: 2007 Electroacoustic - Audiometric equipment - Part 3: Short-term test signals IEC 60645-3: 2007 |
2016/08/07 |
CENELEC |
IN 60645-6: 2010 Electroacoustic - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions IEC 60645-6: 2009 |
2016/08/07 |
CENELEC |
IN 60645-7: 2010 Electroacoustic - Audiometric equipment - Part 7: Instruments for measuring auditory brainstem responses IEC 60645-7: 2009 |
2016/08/07 |
CENELEC |
IN 60669-1: 1999 Switches for household and similar fixed electrical installations - Part 1: General requirements IEC 60669-1: 1998 (Replaced) |
2016/08/07 |
|
EN 60669-1: 1999 / A1: 2002 IEC 60669-1: 1998 / A1: 1999 (Replaced) |
|
|
EN 60669-1: 1999 / A2: 2008 IEC 60669-1: 1998 / A2: 2006 (Changed) |
2016/08/07 |
CENELEC |
EN 60669-2-1: 2004 Switches for household and similar fixed electrical installations - Part 2-1: Special requirements - Electronic switches IEC 60669-2-1: 2002 (Modified) + IS1: 2011 + IS2: 2012 |
2016/08/07 |
|
EN 60669-2-1: 2004 / A1: 2009 IEC 60669-2-1: 2002 / A1: 2008 (Changed) |
|
|
EN 60669-2-1: 2004 / A12: 2010 |
2016/08/07 |
|
EN 60669-2-1: 2004 / AC: 2007 |
|
CENELEC |
EN 60669-2-2: 2006 Switches for household and similar fixed electrical installations - Part 2-2: Special requirements - Electromagnetic remote control switches (RCS) IEC 60669-2-2: 2006 |
2016/08/07 |
CENELEC |
EN 60669-2-3: 2006 Switches for household and similar fixed electrical installations - Part 2-3: Special requirements - Time delay switches (TDS) IEC 60669-2-3: 2006 |
2016/08/07 |
CENELEC |
EN 60669-2-4: 2005 Switches for household and similar fixed electrical installations - Part 2-4: Special requirements - Isolating switches IEC 60669-2-4: 2004 (Replaced) |
2016/08/07 |
CENELEC |
EN 60669-2-6: 2012 Switches for household and similar fixed electrical installations - Part 2-6: Special requirements - Firefighter indoor and outdoor signs and lighting fixtures IEC 60669-2-6: 2012 (Replaced) |
2016/08/07 |
CENELEC |
IN 60670-1: 2005 Electrical accessory boxes and housings for household and similar fixed electrical installations - Part 1: General requirements IEC 60670-1: 2002 (Replaced) |
2016/08/07 |
|
EN 60670-1: 2005 / A1: 2013 IEC 60670-1: 2002 / A1: 2011 (Changed) |
2016/08/07 |
|
EN 60670-1: 2005 / AC: 2007 |
|
|
EN 60670-1: 2005 / AC: 2010 |
|
CENELEC |
IN 60670-21: 2007 Boxes and housings for electrical accessories for household and similar fixed electrical installations - Part 21: Special requirements for boxes and housings with suspension vehicles IEC 60670-21: 2004 (Replaced) |
2016/08/07 |
CENELEC |
IN 60670-22: 2006 Electrical accessory boxes and enclosures for household and similar fixed electrical installations - Part 22: Special requirements for connecting boxes and enclosures IEC 60670-22: 2003 (Replaced) |
2016/08/07 |
CENELEC |
IN 60670-23: 2008 Electrical accessory boxes and enclosures for household and similar fixed electrical installations - Part 23: Special requirements for floor boxes and enclosures IEC 60670-23: 2006 (Replaced) |
2016/08/07 |
CENELEC |
IN 60670-24: 2013 Boxes and housings for electrical accessories for household and similar fixed electrical installations - Part 24: Special requirements for housings for protective devices and other power-consuming electrical equipment IEC 60670-24: 2011 (Changed) |
2016/08/07 |
CENELEC |
AND 60688: 2013 Electrical measuring transducers for converting AC and DC quantities of electricity to analog or digital signals IEC IEC 60688: 2012 |
2016/08/07 |
CENELEC |
AND 60691: 2003 Thermal connections - Requirements and application guide IEC 60691: 2002 |
2016/08/07 |
|
EN 60691: 2003 / A1: 2007 IEC 60691: 2002 / A1: 2006 |
|
|
EN 60691: 2003 / A2: 2010 IEC 60691: 2002 / A2: 2010 |
2016/08/07 |
CENELEC |
IN 60702-1: 2002 Mineral insulated cables and terminals whose nominal voltage does not exceed 750 V - Part 1: Cables IEC 60702-1: 2002 |
2016/08/07 |
|
EN 60702-1: 2002 / A1: 2015 IEC 60702-1: 2002 / A1: 2015 |
2016/08/07 |
CENELEC |
IN 60702-2: 2002 Mineral insulated cables and terminals whose nominal voltage does not exceed 750 V - Part 2: Terminations IEC 60702-2: 2002 |
2016/08/07 |
|
EN 60702-2: 2002 / A1: 2015 IEC 60702-2: 2002 / A1: 2015 |
2016/08/07 |
CENELEC |
AND 60715: 2001 Dimensions of low voltage switchgear and controller - Standard mounting on rails for mechanical support of electrical devices in switches and control systems IEC 60715: 1981 + A1: 1995 |
2016/08/07 |
CENELEC |
AND 60719: 1993 Calculation of upper and lower limits for circular copper conductors and the average external dimensions of cables with nominal voltages up to and including 450 / 750 V IEC 60719: 1992 |
2016/08/07 |
CENELEC |
IN 60728-11: 2010 Cable networks for television signals, audio signals and interactive services - Part 11: Security IEC 60728-11: 2010 |
2016/08/07 |
CENELEC |
IN 60730-1: 2011 Automatic electrical controls for household and similar uses - Part 1: General requirements IEC 60730-1: 2010 (Replaced) |
2016/08/07 |
CENELEC |
IN 60730-1: 1995 Automatic electrical controls for household and similar uses - Part 1: General requirements IEC 60730-1: 1993 (Replaced) |
2016/08/07 |
|
EN 60730-1: 1995 / A1: 1997 IEC 60730-1: 1993 / A1: 1994 (Replaced) |
|
|
EN 60730-1: 1995 / A2: 1998 IEC 60730-1: 1993 / A2: 1997 |
|
|
EN 60730-1: 1995 / A11: 1996 |
|
|
EN 60730-1: 1995 / A12: 1996 |
|
|
EN 60730-1: 1995 / A14: 1998 |
|
|
EN 60730-1: 1995 / A15: 1998 |
|
|
EN 60730-1: 1995 / A16: 1999 |
|
|
EN 60730-1: 1995 / A17: 2000 |
|
|
EN 60730-1: 1995 / A18: 2003 |
2016/08/07 |
|
EN 60730-1: 1995 / AC: 2007 |
|
CENELEC |
EN 60730-2-2: 2002 Automatic electrical controls for household and similar uses - Part 2-2: Special requirements for thermal motor protectors IEC 60730-2-2: 2001 (Replaced) |
2016/08/07 |
|
EN 60730-2-2: 2002 / A1: 2006 IEC 60730-2-2: 2001 / A1: 2005 (Changed) |
|
|
EN 60730-2-2: 2002 / A11: 2005 |
2016/08/07 |
CENELEC |
EN 60730-2-3: 2007 Automatic electrical controls for household and similar uses - Part 2-3: Particular requirements for ballasts for ballasts for tubular fluorescent lamps IEC 60730-2-3: 2006 (Replaced) |
2016/08/07 |
CENELEC |
EN 60730-2-4: 2007 Automatic electrical controls for household and similar uses - Part 2-4: Special requirements for thermal motor protectors for hermetic and semi-hermetic motor compressors IEC 60730-2-4: 2006 (Changed) |
2016/08/07 |
CENELEC |
EN 60730-2-5: 2015 Automatic electrical controls - Part 2-5: Special requirements for automatic electrical burner control systems IEC 60730-2-5: 2013 (Changed) |
2016/08/07 |
CENELEC |
EN 60730-2-6: 2016 Automatic electrical controls - Part 2-6: Specific requirements for automatic electrical pressure sensing controls, including mechanical requirements IEC 60730-2-6: 2015 |
2016/08/07 |
CENELEC |
EN 60730-2-7: 2010 Automatic electrical controls for household and similar uses - Part 2-7: Special requirements for timers and time switches IEC 60730-2-7: 2008 (Changed) |
2016/08/07 |
|
EN 60730-2-7: 2010 / AC: 2011 |
|
CENELEC |
EN 60730-2-8: 2002 Automatic electrical controls for household and similar uses - Part 2-8: Special requirements for electrically operated water valves, including mechanical requirements IEC 60730-2-8: 2000 (Replaced) |
2016/08/07 |
|
EN 60730-2-8: 2002 / A1: 2003 IEC 60730-2-8: 2000 / A1: 2002 (Changed) |
2016/08/07 |
CENELEC |
EN 60730-2-9: 2010 Automatic electrical controls for household and similar uses - Part 2-9: Special requirements for temperature sensing controls IEC 60730-2-9: 2008 (Changed) |
2016/08/07 |
CENELEC |
EN 60730-2-10: 2007 Automatic electrical controls for household and similar uses - Part 2-10: Special requirements for motor start relays IEC 60730-2-10: 2006 |
2016/08/07 |
CENELEC |
EN 60730-2-11: 2008 Automatic electrical controls for household and similar uses - Part 2-11: Special requirements for energy regulators IEC 60730-2-11: 2006 |
2016/08/07 |
CENELEC |
EN 60730-2-12: 2006 Automatic electrical controls for household and similar uses - Part 2-12: Special requirements for electrically operated door locks IEC 60730-2-12: 2005 (Replaced) |
2016/08/07 |
|
EN 60730-2-12: 2006 / A11: 2008 |
2016/08/07 |
CENELEC |
EN 60730-2-13: 2008 Automatic electrical controls for household and similar uses - Part 2-13: Special requirements for humidity detection controls IEC 60730-2-13: 2006 (Changed) |
2016/08/07 |
CENELEC |
EN 60730-2-14: 1997 Automatic electrical controls for household and similar uses - Part 2-14: Special requirements for electric actuators IEC 60730-2-14: 1995 (Replaced) |
2016/08/07 |
|
EN 60730-2-14: 1997 / A1: 2001 IEC 60730-2-14: 1995 / A1: 2001 |
|
|
EN 60730-2-14: 1997 / A2: 2008 IEC 60730-2-14: 1995 / A2: 2007 (Changed) |
|
|
EN 60730-2-14: 1997 / A11: 2005 |
2016/08/07 |
CENELEC |
EN 60730-2-15: 2010 Automatic electrical controls for household and similar uses - Part 2-15: Special requirements for automatic electrical airflow, waterflow and water level detection controls IEC 60730-2-15: 2008 (Changed) |
2016/08/07 |
CENELEC |
EN 60730-2-19: 2002 Automatic electrical controls for household and similar uses - Part 2-19: Specific requirements for electrically operated oil valves, including mechanical requirements IEC 60730-2-19: 1997 (Changed) + A1: 2000 (Changed) |
2016/08/07 |
|
EN 60730-2-19: 2002 / A2: 2008 IEC 60730-2-19: 1997 / A2: 2007 |
|
|
EN 60730-2-19: 2002 / A11: 2005 |
2016/08/07 |
CENELEC |
IN 60754-1: 2014 Testing of gases developing during combustion of materials from cables - Part 1: Determination of halogen acid gas content IEC 60754-1: 2011 |
2016/08/07 |
CENELEC |
IN 60754-2: 2014 Testing gases produced during combustion of materials in cables - Part 2: Determination of acidity (by pH measurement) and conductivity IEC 60754-2: 2011 |
2016/08/07 |
CENELEC |
AND 60799: 1998 Electrical accessories - Cord sets and interconnect cords IEC 60799: 1998 |
2016/08/07 |
CENELEC |
IN 60811-100: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 100: General IEC 60811-100: 2012 |
2016/08/07 |
CENELEC |
IN 60811-201: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness IEC 60811-201: 2012 |
2016/08/07 |
CENELEC |
IN 60811-202: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of non-metallic sheath thickness IEC 60811-202: 2012 |
2016/08/07 |
CENELEC |
IN 60811-203: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of general dimensions IEC 60811-203: 2012 |
2016/08/07 |
CENELEC |
IN 60811-301: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 301: Electrical tests - Permeability measurement of filling compounds at 23 o C IEC 60811-301: 2012 |
2016/08/07 |
CENELEC |
IN 60811-302: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 302: Electrical tests - Measurement of dc resistance of filling compounds at 23 o C and 100 o C IEC 60811-302: 2012 |
2016/08/07 |
CENELEC |
IN 60811-401: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal aging methods - Aging in an air oven IEC 60811-401: 2012 |
2016/08/07 |
CENELEC |
IN 60811-402: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests IEC 60811-402: 2012 |
2016/08/07 |
CENELEC |
IN 60811-403: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds IEC 60811-403: 2012 |
2016/08/07 |
CENELEC |
IN 60811-404: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Immersion tests for sheaths IEC 60811-404: 2012 |
2016/08/07 |
CENELEC |
IN 60811-405: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths IEC 60811-405: 2012 |
2016/08/07 |
CENELEC |
IN 60811-406: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 406: Miscellaneous tests - Resistance to stress cracking of polyethylene and polypropylene compounds IEC 60811-406: 2012 |
2016/08/07 |
CENELEC |
IN 60811-407: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 407: Miscellaneous tests - Measurement of mass increase of polyethylene and polypropylene compounds IEC 60811-407: 2012 |
2016/08/07 |
CENELEC |
IN 60811-408: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 408: Miscellaneous tests - Long-term stability testing of polyethylene and polypropylene compounds IEC 60811-408: 2012 |
2016/08/07 |
CENELEC |
IN 60811-409: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Thermoplastic insulation and loss of mass test for sheaths IEC 60811-409: 2012 |
2016/08/07 |
CENELEC |
IN 60811-410: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 410: Miscellaneous tests - Test method for copper catalyzed oxidative degradation of polyolefin insulated conductors IEC 60811-410: 2012 |
2016/08/07 |
CENELEC |
IN 60811-411: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 411: Miscellaneous tests - Low temperature brittleness of filling compounds IEC 60811-411: 2012 |
2016/08/07 |
CENELEC |
IN 60811-412: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal aging methods - Aging in an air bomb IEC 60811-412: 2012 |
2016/08/07 |
CENELEC |
IN 60811-501: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for the determination of mechanical properties of insulation and coating compounds IEC 60811-501: 2012 |
2016/08/07 |
CENELEC |
IN 60811-502: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulation IEC 60811-502: 2012 |
2016/08/07 |
CENELEC |
IN 60811-503: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths IEC 60811-503: 2012 |
2016/08/07 |
CENELEC |
IN 60811-504: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Low temperature bending tests for insulation and sheaths IEC 60811-504: 2012 |
2016/08/07 |
CENELEC |
IN 60811-505: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Insulation and low temperature elongation for sheaths IEC 60811-505: 2012 |
2016/08/07 |
CENELEC |
IN 60811-506: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Low temperature impact test for insulation and sheaths IEC 60811-506: 2012 |
2016/08/07 |
CENELEC |
IN 60811-507: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials IEC 60811-507: 2012 |
2016/08/07 |
CENELEC |
IN 60811-508: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 508: Mechanical tests - High temperature pressure test for insulation and sheaths IEC 60811-508: 2012 |
2016/08/07 |
CENELEC |
IN 60811-509: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test the cracking resistance of insulation and insulation materials (heat shock test) IEC 60811-509: 2012 |
2016/08/07 |
CENELEC |
IN 60811-510: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Specific methods for polyethylene and polypropylene compounds - Winding test after thermal aging in air IEC 60811-510: 2012 |
2016/08/07 |
CENELEC |
IN 60811-511: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 511: Mechanical tests - Measurement of melt flow index of polyethylene compounds IEC 60811-511: 2012 |
2016/08/07 |
CENELEC |
IN 60811-512: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 512: Mechanical tests - Special methods for polyethylene and polypropylene compounds - Tensile strength and elongation at break after high temperature conditioning IEC 60811-512: 2012 |
2016/08/07 |
CENELEC |
IN 60811-513: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Specific methods for polyethylene and polypropylene compounds - Winding test after conditioning IEC 60811-513: 2012 |
2016/08/07 |
CENELEC |
IN 60811-601: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the dropping point of filling compounds IEC 60811-601: 2012 |
2016/08/07 |
CENELEC |
IN 60811-602: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 602: Physical tests - Separation of oil in filling compounds IEC 60811-602: 2012 |
2016/08/07 |
CENELEC |
IN 60811-603: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 603: Physical tests - Measurement of the total acid number of filling compounds IEC 60811-603: 2012 |
2016/08/07 |
CENELEC |
IN 60811-604: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 604: Physical tests - Measurement of the absence of abrasive components in filler compounds IEC 60811-604: 2012 |
2016/08/07 |
CENELEC |
IN 60811-605: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 605: Physical tests - Measurement of carbon black and / or mineral filler in polyethylene compounds IEC 60811-605: 2012 |
2016/08/07 |
CENELEC |
IN 60811-606: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determination of density IEC 60811-606: 2012 |
2016/08/07 |
CENELEC |
IN 60811-607: 2012 Electrical and fiber optic cables - Test methods for non-metallic materials - Part 607: Physical tests - Test for the evaluation of carbon black dispersion in polyethylene and polypropylene IEC 60811-607: 2012 |
2016/08/07 |
CENELEC |
IN 60825-1: 2014 Safety of laser products - Part 1: Equipment classification and requirements IEC 60825-1: 2014 |
2016/08/07 |
CENELEC |
IN 60825-2: 2004 Safety of laser products - Part 2: Security of optical fiber communication systems (OFCS) IEC 60825-2: 2004 |
2016/08/07 |
|
EN 60825-2: 2004 / A1: 2007 IEC 60825-2: 2004 / A1: 2006 |
|
|
EN 60825-2: 2004 / A2: 2010 IEC 60825-2: 2004 / A2: 2010 |
2016/08/07 |
CENELEC |
IN 60825-4: 2006 Safety of laser products - Part 4: Laser protections IEC 60825-4: 2006 |
2016/08/07 |
|
EN 60825-4: 2006 / A1: 2008 IEC 60825-4: 2006 / A1: 2008 |
|
|
EN 60825-4: 2006 / A2: 2011 IEC 60825-4: 2006 / A2: 2011 |
2016/08/07 |
CENELEC |
IN 60825-12: 2004 Safety of laser products - Part 12: Security of free-space optical communication systems for information transmission IEC 60825-12: 2004 |
2016/08/07 |
CENELEC |
IN 60831-1: 2014 1 000 V - Section 1: General - Self-healing shunt power capacitors for AC systems with rated voltage, including performance, testing and evaluation - Safety requirements - Installation and operating instructions IEC 60831-1: 2014 |
2016/08/07 |
|
EN 60831-1: 2014 / AC: 2014 |
|
CENELEC |
IN 60831-2: 2014 1 000 V - Part 2: Self-healing shunt power capacitors for ac systems with nominal voltage, including aging test, self-healing test and destruction test IEC 60831-2: 2014 |
2016/08/07 |
CENELEC |
IN 60838-1: 2004 Miscellaneous lamps - Part 1: General requirements and tests IEC 60838-1: 2004 |
2016/08/07 |
|
EN 60838-1: 2004 / A1: 2008 IEC 60838-1: 2004 / A1: 2008 |
|
|
EN 60838-1: 2004 / A2: 2011 IEC 60838-1: 2004 / A2: 2011 |
2016/08/07 |
CENELEC |
EN 60838-2-1: 1996 Miscellaneous lampholders - Part 2: Special requirements - Part 1: Lampholders S14 IEC 60838-2-1: 1994 |
2016/08/07 |
|
EN 60838-2-1: 1996 / A1: 1998 IEC 60838-2-1: 1994 / A1: 1998 |
|
|
EN 60838-2-1: 1996 / A2: 2004 2-1: 1994 / A2: 2004 |
2016/08/07 |
CENELEC |
EN 60838-2-2: 2006 Miscellaneous brackets - Part 2-2: Special requirements - Connectors for LED modules IEC 60838-2-2: 2006 |
2016/08/07 |
|
EN 60838-2-2: 2006 / A1: 2012 IEC 60838-2-2: 2006 / A1: 2012 |
2016/08/07 |
CENELEC |
IN 60898-1: 2003 Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit breakers for AC operation IEC 60898-1: 2002 (Replaced) |
2016/08/07 |
|
EN 60898-1: 2003 / A1: 2004 IEC 60898-1: 2002 / A1: 2002 (Replaced) |
|
|
EN 60898-1: 2003 / A11: 2005 |
|
|
EN 60898-1: 2003 / A13: 2012 |
2016/08/07 |
|
EN 60898-1: 2003 / AC: 2004 |
|
CENELEC |
IN 60898-2: 2006 Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 2: Circuit breakers for AC and DC operation IEC 60898-2: 2000 (Changed) + A1: 2003 (Changed) |
2016/08/07 |
CENELEC |
IN 60931-1: 1996 Self-healing type power capacitors for ac systems with rated voltage up to 1 kV and including 1 kV - Part 1: General - Performance, testing and evaluation - Safety requirements - Installation and operating instructions IEC 60931-1: 1996 |
2016/08/07 |
|
EN 60931-1: 1996 / A1: 2003 IEC 60931-1: 1996 / A1: 2002 |
2016/08/07 |
CENELEC |
IN 60931-2: 1996 Self-healing type power capacitors for ac systems with rated voltage up to and including 1 kV - Part 2: Aging test and destruction test IEC 60931-2: 1995 |
2016/08/07 |
CENELEC |
IN 60931-3: 1996 1 kV - Part 3: shunt power capacitors of self-healing type for AC systems with rated voltage including: Internal fuses IEC 60931-3: 1996 |
2016/08/07 |
CENELEC |
AND 60934: 2001 Circuit breakers for equipment (CBE) IEC 60934: 2000 |
2016/08/07 |
|
EN 60934: 2001 / A1: 2007 IEC 60934: 2000 / A1: 2007 |
|
|
EN 60934: 2001 / A2: 2013 IEC 60934: 2000 / A2: 2013 |
2016/08/07 |
CENELEC |
IN 60947-1: 2007 Low-voltage switchgear and control - Part 1: General rules IEC 60947-1: 2007 |
2016/08/07 |
|
EN 60947-1: 2007 / A1: 2011 IEC 60947-1: 2007 / A1: 2010 |
|
|
EN 60947-1: 2007 / A2: 2014 IEC 60947-1: 2007 / A2: 2014 |
2016/08/07 |
CENELEC |
IN 60947-2: 2006 Low-voltage switchgear and control - Part 2: Circuit breakers IEC 60947-2: 2006 |
2016/08/07 |
|
EN 60947-2: 2006 / A1: 2009 IEC 60947-2: 2006 / A1: 2009 |
|
|
EN 60947-2: 2006 / A2: 2013 IEC 60947-2: 2006 / A2: 2013 |
2016/08/07 |
CENELEC |
IN 60947-3: 2009 Low-voltage switchgear and controls - Part 3: Switches, disconnectors, disconnectors and fuse-combination units IEC 60947-3: 2008 |
2016/08/07 |
|
EN 60947-3: 2009 / A1: 2012 IEC 60947-3: 2008 / A1: 2012 |
|
|
EN 60947-3: 2009 / A2: 2015 IEC 60947-3: 2008 / A2: 2015 |
2016/08/07 |
CENELEC |
EN 60947-4-1: 2010 Low-voltage switchgear and control - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters IEC 60947-4-1: 2009 |
2016/08/07 |
|
EN 60947-4-1: 2010 / A1: 2012 IEC 60947-4-1: 2009 / A1: 2012 |
2016/08/07 |
CENELEC |
EN 60947-4-2: 2012 Low voltage switchgear and controllers - Part 4-2: Contactors and motor starters - AC semiconductor motor controllers and starters IEC 60947-4-2: 2011 |
2016/08/07 |
CENELEC |
EN 60947-4-3: 2014 Low voltage switchgear and control unit - Part 4-3: Contactors and motor starters - AC semiconductor controllers and contactors for non-motorized loads IEC 60947-4-3: 2014 |
2016/08/07 |
CENELEC |
EN 60947-5-1: 2004 Low-voltage switchgear and controls - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices IEC 60947-5-1: 2003 |
2016/08/07 |
|
EN 60947-5-1: 2004 / A1: 2009 IEC 60947-5-1: 2003 / A1: 2009 |
2016/08/07 |
|
EN 60947-5-1: 2004 / AC: 2004 |
|
|
EN 60947-5-1: 2004 / AC: 2005 |
|
CENELEC |
EN 60947-5-2: 2007 Low-voltage switchgear and controls - Part 5-2: Control circuit devices and switching elements - Proximity switches IEC 60947-5-2: 2007 |
2016/08/07 |
|
EN 60947-5-2: 2007 / A1: 2012 IEC 60947-5-2: 2007 / A1: 2012 |
2016/08/07 |
CENELEC |
EN 60947-5-4: 2003 Low-voltage switchgear and controller - Part 5-4: Control circuit devices and switching elements - Method for evaluating the performance of low-energy contacts - Special tests IEC 60947-5-4: 2002 |
2016/08/07 |
CENELEC |
EN 60947-5-5: 1997 Low-voltage switchgear and controller - Part 5-5: Control circuit devices and switching elements - Electrical emergency stop device with mechanical locking function IEC 60947-5-5: 1997 |
2016/08/07 |
|
EN 60947-5-5: 1997 / A1: 2005 IEC 60947-5-5: 1997 / A1: 2005 |
|
|
EN 60947-5-5: 1997 / A11: 2013 |
2016/08/07 |
CENELEC |
EN 60947-5-7: 2003 Low-voltage switchgear and controls - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analog output IEC 60947-5-7: 2003 |
2016/08/07 |
CENELEC |
EN 60947-5-8: 2006 Low-voltage switchgear and controls - Part 5-8: Control circuit devices and switching elements - Three-position enable switches IEC 60947-5-8: 2006 |
2016/08/07 |
CENELEC |
EN 60947-5-9: 2007 Low-voltage switchgear and controller - Part 5-9: Control circuit devices and switching elements - Flow rate switches IEC 60947-5-9: 2006 |
2016/08/07 |
CENELEC |
EN 60947-6-1: 2005 Low-voltage switchgear and control - Part 6-1: Multifunctional equipment - Transfer switching equipment IEC 60947-6-1: 2005 |
2016/08/07 |
|
EN 60947-6-1: 2005 / A1: 2014 IEC 60947-6-1: 2005 / A1: 2013 |
2016/08/07 |
CENELEC |
EN 60947-6-2: 2003 Low-voltage switchgear and controls - Part 6-2: Multifunctional equipment - Control and protective switching devices (or equipment) (CPS) IEC 60947-6-2: 2002 |
2016/08/07 |
|
EN 60947-6-2: 2003 / A1: 2007 IEC 60947-6-2: 2002 / A1: 2007 |
2016/08/07 |
CENELEC |
EN 60947-7-1: 2009 Low Voltage Switchgear and Control Unit - Part 7-1: Auxiliary Equipment - Terminal Blocks for Copper Conductors IEC 60947-7-1: 2009 |
2016/08/07 |
CENELEC |
EN 60947-7-2: 2009 Low voltage switchgear and controlgear - Part 7-2: Auxiliary equipment - Protective conductor terminal blocks for copper conductors IEC 60947-7-2: 2009 |
2016/08/07 |
CENELEC |
EN 60947-7-3: 2009 Low-voltage switchgear and controller - Part 7-3: Auxiliary equipment - Safety requirements for fuse terminals IEC 60947-7-3: 2009 |
2016/08/07 |
CENELEC |
IN 60947-8: 2003 Low-voltage switchgear and controller - Part 8: Internal thermal protection (PTC) controllers for rotating electrical machines IEC 60947-8: 2003 |
2016/08/07 |
|
EN 60947-8: 2003 / A1: 2006 IEC 60947-8: 2003 / A1: 2006 |
|
|
EN 60947-8: 2003 / A2: 2012 IEC 60947-8: 2003 / A2: 2011 |
2016/08/07 |
CENELEC |
IN 60950-21: 2003 Information technology devices - Safety - Part 21: Remote power supply IEC 60950-21: 2002 |
2016/08/07 |
CENELEC |
IN 60950-22: 2006 Information technology equipment - Safety - Part 22: Outdoor equipment IEC 60950-22: 2005 (Replaced) |
2016/08/07 |
|
EN 60950-22: 2006 / AC: 2008 |
|
CENELEC |
IN 60950-23: 2006 Information technology devices - Security - Part 23: Big data storage equipment IEC 60950-23: 2005 |
2016/08/07 |
|
EN 60950-23: 2006 / AC: 2008 |
|
CENELEC |
AND 60968: 2015 Self-ballast fluorescent lamps for general lighting services - Safety requirements IEC 60968: 2015 (Changed) IEC 60968: 2015 / COR1: 2015 (Changed) |
2016/08/07 |
CENELEC |
IN 60974-1: 2012 Arc welding equipment - Part 1: Welding power supplies IEC 60974-1: 2012 |
2016/08/07 |
CENELEC |
IN 60974-2: 2013 Arc welding - Part 2: Liquid cooling systems IEC 60974-2: 2013 |
2016/08/07 |
CENELEC |
IN 60974-3: 2014 Arc welding - Part 3: Arc striking and balancing devices IEC 60974-3: 2013 |
2016/08/07 |
CENELEC |
IN 60974-5: 2013 Arc welding - Part 5: Wire feeders IEC 60974-5: 2013 |
2016/08/07 |
CENELEC |
IN 60974-6: 2016 Arc welding equipment - Part 6: Limited duty equipment IEC 60974-6: 2015 |
2016/08/07 |
CENELEC |
IN 60974-7: 2013 Arc welding - Part 7: Torches IEC 60974-7: 2013 |
2016/08/07 |
CENELEC |
IN 60974-8: 2009 Arc welding machines - Part 8: Gas consoles for welding and plasma cutting systems IEC 60974-8: 2009 |
2016/08/07 |
CENELEC |
IN 60974-11: 2010 Arc welding - Part 11: Electrode holders IEC 60974-11: 2010 |
2016/08/07 |
CENELEC |
IN 60974-12: 2011 Arc welding machines - Part 12: Coupling devices for welding cables IEC 60974-12: 2011 |
2016/08/07 |
CENELEC |
IN 60974-13: 2011 Arc welding - Part 13: Welding clamp IEC 60974-13: 2011 |
2016/08/07 |
CENELEC |
IN 60998-1: 2004 Connection devices for low-voltage circuits for household and similar purposes - Part 1: General requirements IEC 60998-1: 2002 (Replaced) |
2016/08/07 |
CENELEC |
EN 60998-2-1: 2004 Connection devices for low-voltage circuits for household and similar purposes - Part 2-1: Special requirements for connecting devices as separate devices with screw clamping units IEC 60998-2-1: 2002 (Replaced) |
2016/08/07 |
CENELEC |
EN 60998-2-2: 2004 Connection devices for low-voltage circuits for household and similar purposes - Part 2-2: Special requirements for connecting screwless type clamping units and devices as separate units IEC 60998-2-2: 2002 (Replaced) |
2016/08/07 |
CENELEC |
EN 60998-2-3: 2004 Connection devices for low-voltage circuits for household and similar purposes - Part 2-3: Special requirements for the connection of insulating piercing clamping units and devices as separate units IEC 60998-2-3: 2002 (Replaced) |
2016/08/07 |
CENELEC |
EN 60998-2-4: 2005 Connection devices for low-voltage circuits for household and similar purposes - Part 2-4: Special requirements for twist connection devices IEC 60998-2-4: 2004 (Replaced) |
2016/08/07 |
CENELEC |
IN 60999-1: 2000 Connection devices - Electrical copper conductors - Safety requirements for screw and screwless type crimping units - Part 1: General requirements and special requirements for crimping units for 0,2 mm 2 to 35 mm 2 conductors (included) IEC 60999-1: 1999 |
2016/08/07 |
CENELEC |
IN 60999-2: 2003 Connection devices - Electrical copper conductors - Safety requirements for screw and screwless type clamping units - Part 2: Special requirements for clamping units for conductors over 35 mm 2 to 300 mm 2 (included) IEC 60999-2: 2003 |
2016/08/07 |
CENELEC |
IN 61008-1: 2012 Residual current circuit breakers (RCCBs) without integrated overcurrent protection for domestic and similar uses - Part 1: General rules IEC 61008-1: 2010 (Changed) |
2016/08/07 |
|
EN 61008-1: 2012 / A1: 2014 IEC 61008-1: 2010 / A1: 2012 (Replaced) |
2016/08/07 |
|
EN 61008-1: 2012 / A2: 2014 IEC 61008-1: 2010 / A2: 2013 (Changed) |
2016/08/07 |
|
EN 61008-1: 2012 / A11: 2015 |
2016/08/07 |
CENELEC |
EN 61008-2-1: 1994 Residual current circuit breakers (RCCBs) without integrated overcurrent protection for domestic and similar uses - Part 2-1: Functional applicability of the general rules independently of the line voltage of the RCCB IEC 61008-2-1: 1990 |
2016/08/07 |
|
EN 61008-2-1: 1994 / A11: 1998 |
2016/08/07 |
|
EN 61008-2-1: 1994 / A11 |
|
CENELEC |
IN 61009-1: 2012 Residual current circuit breakers (RCBOs) with integrated overcurrent protection for domestic and similar uses - Part 1: General rules IEC 61009-1: 2010 (Changed) |
2016/08/07 |
|
EN 61009-1: 2012 / A1: 2014 IEC 61009-1: 2010 / A1: 2012 (Replaced) |
2016/08/07 |
|
EN 61009-1: 2012 / A2: 2014 IEC 61009-1: 2010 / A2: 2013 (Changed) |
2016/08/07 |
|
EN 61009-1: 2012 / A11: 2015 |
2016/08/07 |
CENELEC |
EN 61009-2-1: 1994 Residual current circuit breakers (RCBOs) with integrated overcurrent protection for domestic and similar uses - Part 2-1: Functional applicability of general rules to RCBO independently of line voltage IEC 61009-2-1: 1991 |
2016/08/07 |
|
EN 61009-2-1: 1994 / A11: 1998 |
2016/08/07 |
|
EN 61009-2-1: 1994 / A11 |
|
CENELEC |
IN 61010-1: 2010 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements IEC 61 IEC 61010-1: 2010 |
2016/08/07 |
CENELEC |
EN 61010-2-010: 2014 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Specific requirements for laboratory equipment for heating materials IEC 61010-2-010: 2014 |
2016/08/07 |
CENELEC |
EN 61010-2-020: 2006 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-020: Specific requirements for laboratory centrifuges IEC 61010-2-020: 2006 |
2016/08/07 |
CENELEC |
EN 61010-2-030: 2010 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-030: Specific requirements for test and measuring circuits IEC 61010- IEC 61010-2-030: 2010 |
2016/08/07 |
CENELEC |
EN 61010-2-032: 2012 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Specific requirements for hand-held and hand-held current sensors for electrical testing and measurement IEC 61010-2-032: 2012 |
2016/08/07 |
CENELEC |
EN 61010-2-033: 2012 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-033: For local and professional use, it is capable of measuring hand voltage and special requirements for other measuring devices, capable of measuring mains voltage. IEC 61010-2-033: 2012 |
2016/08/07 |
CENELEC |
EN 61010-2-040: 2005 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-040: Special requirements for sterilizers and washer-disinfectors for the treatment of medical equipment IEC 61010-2-040: 2005 |
2016/08/07 |
CENELEC |
EN 61010-2-051: 2015 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Specific requirements for laboratory equipment for mixing and mixing IEC 61010-2-051: 2015 |
2016/08/07 |
CENELEC |
EN 61010-2-061: 2003 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for thermal atomization and ionization and laboratory atomic spectrometers IEC 61010-2-061: 2003 |
2016/08/07 |
CENELEC |
EN 61010-2-201: 2013 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-201: Specific requirements for control equipment IEC 61010-2-201: 2013 |
2016/08/07 |
|
EN 61010-2-201: 2013 / AC: 2013 |
|
CENELEC |
IN 61010-031: 2015 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and testing IEC 61010-031: 2015 |
2016/08/07 |
CENELEC |
AND 61028: 1993 Electrical measuring instruments - XY recorders IEC 61028: 1991 |
2016/08/07 |
|
EN 61028: 1993 / A2: 1997 IEC 61028: 1991 / A2: 1997 |
2016/08/07 |
CENELEC |
IN 61034-1: 2005 Measurement of smoke density of burned cables under defined conditions - Part 1: Test apparatus IEC 61034-1: 2005 |
2016/08/07 |
|
EN 61034-1: 2005 / A1: 2014 IEC 61034-1: 2005 / A1: 2013 |
2016/08/07 |
CENELEC |
IN 61034-2: 2005 Measurement of smoke density of burned cables under defined conditions - Part 2: Test procedure and requirements IEC 61034-2: 2005 |
2016/08/07 |
|
EN 61034-2: 2005 / A1: 2013 IEC 61034-2: 2005 / A1: 2013 |
2016/08/07 |
CENELEC |
AND 61048: 2006 Auxiliary lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements IEC 61048: 2006 |
2016/08/07 |
|
EN 61048: 2006 / A1: 2016 IEC 61048: 2006 / A1: 2015 |
2016/08/07 |
CENELEC |
AND 61050: 1992 Transformers for tubular discharge lamps with no-load output voltage exceeding 1 kV (often called neon transformers) - General and safety requirements IEC 61050: 1991 (Replaced) |
2016/08/07 |
|
EN 61050: 1992 / A1: 1995 IEC 61050: 1991 / A1: 1994 (Replaced) |
2016/08/07 |
CENELEC |
IN 61058-1: 2002 Switches for Devices - Part 1: General requirements IEC 61058-1: 2000 (Changed) + A1: 2001 |
2016/08/07 |
|
EN 61058-1: 2002 / A2: 2008 IEC 61058-1: 2000 / A2: 2007 |
2016/08/07 |
CENELEC |
EN 61058-2-1: 2011 Switches for Devices - Part 2-1: Special requirements for cable switches IEC 61058-2-1: 2010 |
2016/08/07 |
CENELEC |
EN 61058-2-4: 2005 Switches for Devices - Part 2-4: Special requirements for independently mounted switches IEC 61058-2-4: 1995 + A1: 2003 |
2016/08/07 |
CENELEC |
EN 61058-2-5: 2011 Switches for Devices - Part 2-5: Special requirements for variable selectors IEC 61058-2-5: 2010 |
2016/08/07 |
CENELEC |
AND 61071: 2007 Capacitors for power electronics IEC 61071: 2007 |
2016/08/07 |
CENELEC |
AND 61095: 2009 Electromechanical contactors for household and similar purposes IEC 61095: 2009 |
2016/08/07 |
CENELEC |
IN 61131-2: 2007 Programmable controllers - Part 2: Equipment requirements and tests IEC 61131-2: 2007 |
2016/08/07 |
CENELEC |
AND 61138: 2007 Cables for portable grounding and short-circuit equipment IEC 61138: 2007 (Changed) |
2016/08/07 |
CENELEC |
AND 61140: 2002 Protection against electric shock - Common aspects for installation and equipment IEC 61140: 2001 |
2016/08/07 |
|
EN 61140: 2002 / A1: 2006 IEC 61140: 2001 / A1: 2004 (Replaced) |
2016/08/07 |
CENELEC |
IN 61143-1: 1994 Electrical measuring devices - Xt recorders - Part 1: Definitions and requirements IEC 61143-1: 1992 |
2016/08/07 |
|
EN 61143-1: 1994 / A1: 1997 IEC 61143-1: 1992 / A1: 1997 |
2016/08/07 |
CENELEC |
IN 61143-2: 1994 Electrical measuring devices - Xt recorders - Part 2: Recommended additional test methods IEC 61143-2: 1992 |
2016/08/07 |
CENELEC |
AND 61184: 2008 Bayonet lamps IEC IEC 61184: 2008 |
2016/08/07 |
|
EN 61184: 2008 / A1: 2011 |
2016/08/07 |
CENELEC |
AND 61187: 1994 Electrical and electronic measuring instruments - Documentation IEC 61187: 1993 (Replaced) |
2016/08/07 |
|
EN 61187: 1994 / AC: 1995 |
|
CENELEC |
AND 61195: 1999 Double-cap fluorescent lamps - Safety features IEC 61195: 1999 |
2016/08/07 |
|
EN 61195: 1999 / A1: 2013 IEC 61195: 1999 / A1: 2012 |
|
|
EN 61195: 1999 / A2: 2015 IEC 61195: 1999 / A2: 2014 |
2016/08/07 |
CENELEC |
AND 61199: 2011 Single-cap fluorescent lamps - Safety features IEC 61199: 2011 |
2016/08/07 |
|
EN 61199: 2011 / A1: 2013 IEC 61199: 2011 / A1: 2012 |
|
|
EN 61199: 2011 / A2: 2015 IEC 61199: 2011 / A2: 2014 |
2016/08/07 |
CENELEC |
AND 61204: 1995 Low-voltage power supply devices, dc output - Performance characteristics IEC 61204: 1993 (Replaced) |
2016/08/07 |
CENELEC |
IN 61204-7: 2006 Low voltage power supplies, dc output - Part 7: Safety requirements IEC 61204-7: 2006 |
2016/08/07 |
|
EN 61204-7: 2006 / A11: 2009 |
2016/08/07 |
CENELEC |
AND 61210: 2010 Connection devices - Straight-speed connection terminations for electrical copper conductors - Safety requirements IEC 61210: 2010 (Changed) |
2016/08/07 |
CENELEC |
AND 61242: 1997 Electrical accessories - cable reels for household and similar purposes IEC 61242: 1995 (Replaced) |
2016/08/07 |
|
EN 61242: 1997 / A1: 2008 IEC 61242: 1995 / A1: 2008 |
|
|
EN 61242: 1997 / A2: 2016 IEC 61242: 1995 / A2: 2015 |
2016/08/07 |
|
EN 61242: 1997 / A1: 2008 / AC: 2010 |
|
CENELEC |
IN 61243-3: 2014 Live operation - Voltage detectors - Section 3: Two-pole low voltage type IEC 61243-3: 2014 |
2016/08/07 |
|
EN 61243-3: 2014 / AC: 2015 |
|
|
EN 61243-3: 2014 / AC: 2015 |
|
CENELEC |
IN 61270-1: 1996 Condensers for microwave ovens - Part 1: General IEC 61270-1: 1996 |
2016/08/07 |
CENELEC |
AND 61293: 1994 Marking of electrical equipment with ratings for the electrical supply - Safety requirements IEC 61293: 1994 |
2016/08/07 |
CENELEC |
IN 61310-1: 2008 Safety of machines - Indication, marking and operation - Part 1: Requirements for visual, acoustic and tactile signals IEC 61310-1: 2007 |
2016/08/07 |
CENELEC |
IN 61310-2: 2008 Machine safety - Marking, marking and actuating - Part 2: Requirements for marking IEC 61310-2: 2007 |
2016/08/07 |
CENELEC |
IN 61310-3: 2008 Safety of machinery - Indication, marking and actuating - Part 3: Requirements for the position and operation of the actuators IEC 61310-3: 2007 |
2016/08/07 |
CENELEC |
AND 61316: 1999 Industrial cable reels IEC 61316: 1999 |
2016/08/07 |
CENELEC |
IN 61347-1: 2015 Lamp controlgear - Part 1: General and safety requirements IEC 61347-1: 2015 |
2016/08/07 |
CENELEC |
EN 61347-2-2: 2012 Lamp controlgear - Part 2-2: Particular requirements for electronic cascade converters supplied by dc or ac for filament lamps IEC 61347-2-2: 2011 |
2016/08/07 |
CENELEC |
EN 61347-2-3: 2011 Lamp control gear - Part 2-3: Special requirements for electronic control gears provided by ac and / or dc for fluorescent lamps IEC 6134 IEC 61347-2-3: 2011 |
2016/08/07 |
|
EN 61347-2-3: 2011 / AC: 2011 |
|
CENELEC |
EN 61347-2-7: 2012 Lamp controlgear - Part 2-7: Special requirements for the electronic controller supplied with battery for emergency lighting (independent) IEC 61347-2-7: 2011 |
2016/08/07 |
CENELEC |
EN 61347-2-8: 2001 Lamp controlgear - Part 2-8: Special requirements for ballasts for fluorescent lamps IEC 61347-2-8: 2000 |
2016/08/07 |
|
EN 61347-2-8: 2001 / A1: 2006 2-8: 2000 / A1: 2006 |
2016/08/07 |
|
EN 61347-2-8: 2001 / AC: 2003 |
|
|
EN 61347-2-8: 2001 / AC: 2010 |
|
CENELEC |
EN 61347-2-9: 2013 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic control for discharge lamps (excluding fluorescent lamps) IEC 61347-2-9: 2012 |
2016/08/07 |
CENELEC |
EN 61347-2-10: 2001 Lamp controlgear - Part 2-10: Particular requirements for electronic inverters and converters for high-frequency operation of discharge lamps (neon tubes) with cold start tubes IEC 61347-2-10: 2000 |
2016/08/07 |
|
EN 61347-2-10: 2001 / A1: 2009 IEC 61347-2-10: 2000 / A1: 2008 |
2016/08/07 |
|
EN 61347-2-10: 2001 / AC: 2010 |
|
CENELEC |
EN 61347-2-11: 2001 Lamp controlgear - Part 2-11: Special requirements for various electronic circuits used in luminaires IEC 61347-2-11: 2001 |
2016/08/07 |
|
EN 61347-2-11: 2001 / AC: 2002 |
|
|
EN 61347-2-11: 2001 / AC: 2010 |
|
CENELEC |
EN 61347-2-12: 2005 Lamp controlgear - Part 2-12: Special requirements for dc or ac powered electronic ballasts for discharge lamps (excluding fluorescent lamps) IEC 61347-2-12: 2005 |
2016/08/07 |
|
EN 61347-2-12: 2005 / A1: 2010 IEC 61347-2-12: 2005 / A1: 2010 |
2016/08/07 |
|
EN 61347-2-12: 2005 / AC: 2010 |
|
CENELEC |
EN 61347-2-13: 2014 Lamp controlgear - Part 2-13: Special requirements for electronic control with DC or AC supply for LED modules IEC 61347-2-13: 2014 |
2016/08/07 |
CENELEC |
IN 61386-1: 2008 Cable systems for cable management - Part 1: General requirements IEC 61386-1: 2008 |
2016/08/07 |
CENELEC |
IN 61386-21: 2004 Cable systems for cable management - Part 21: Special requirements - Rigid pipe systems IEC 61386-21: 2002 |
2016/08/07 |
|
EN 61386-21: 2004 / A11: 2010 |
2016/08/07 |
|
EN 61386-21: 2004 / AC: 2004 |
|
CENELEC |
IN 61386-22: 2004 Piping systems for cable management - Part 22: Special requirements - Flexible piping systems IEC 61386-22: 2002 |
2016/08/07 |
|
EN 61386-22: 2004 / A11: 2010 |
2016/08/07 |
|
EN 61386-22: 2004 / AC: 2004 |
|
CENELEC |
IN 61386-23: 2004 Cable systems for cable management - Part 23: Special requirements - Flexible pipe systems IEC 61386-23: 2002 |
2016/08/07 |
|
EN 61386-23: 2004 / A11: 2010 |
2016/08/07 |
|
EN 61386-23: 2004 / AC: 2004 |
|
CENELEC |
IN 61386-24: 2010 Cable systems for cable management - Part 24: Special requirements - Buried pipe systems IEC 61386-24: 2004 |
2016/08/07 |
CENELEC |
IN 61386-25: 2011 Pipe systems for cable management - Part 25: Special requirements - Pipe fixing devices IEC 61386-25: 2011 |
2016/08/07 |
CENELEC |
IN 61439-1: 2011 Low Voltage Switching and Control Devices - Part 1: General Rules IEC 61439-1: 2011 |
2016/08/07 |
CENELEC |
IN 61439-2: 2011 Low Voltage Switching and Control Equipments - Part 2: Power Switchgear and Control Units IEC 61439-2: 2011 |
2016/08/07 |
CENELEC |
IN 61439-3: 2012 Low-voltage switchgear and control devices - Part 3: Distribution panels (DBO) intended for ordinary operation IEC 61439-3: 2012 |
2016/08/07 |
CENELEC |
IN 61439-4: 2013 Low-voltage switchgear and controls - Part 4: Special requirements for installation on construction sites (ACS) IEC 61439-4: 2012 |
2016/08/07 |
CENELEC |
IN 61439-5: 2015 Low-voltage switchgear and controls - Part 5: Installation for power distribution in public networks IEC 61439-5: 2014 |
2016/08/07 |
|
EN 61439-5: 2015 / AC: 2015 |
|
CENELEC |
IN 61439-6: 2012 Low voltage switchgear and control devices - Part 6: Busbar trunking systems (bus lanes) IEC 61439-6: 2012 |
2016/08/07 |
CENELEC |
IN 61534-1: 2011 Powertrack systems - Part 1: General requirements IEC 61 IEC 61534-1: 2011 |
2016/08/07 |
|
EN 61534-1: 2011 / A1: 2014 IEC 61534-1: 2011 / A1: 2014 |
2016/08/07 |
CENELEC |
IN 61534-21: 2014 Powertrack systems - Part 21: Special requirements for power transmission systems designed for wall and ceiling mounting IEC 61534-21: 2014 |
2016/08/07 |
CENELEC |
IN 61534-22: 2014 Powertrack systems - Part 22: Special requirements for powertrack systems designed for surface or bottom mounting IEC 61534-22: 2014 |
2016/08/07 |
CENELEC |
AND 61535: 2009 Mounting couplers designed for permanent connection in fixed installations IEC 61535: 2009 (Changed) |
2016/08/07 |
|
EN 61535: 2009 / A1: 2013 IEC 61535: 2009 / A1: 2012 |
2016/08/07 |
CENELEC |
AND 61537: 2007 Cable management - Cable tray systems and cable ladder systems IEC 61537: 2006 |
2016/08/07 |
CENELEC |
AND 61549: 2003 Various lamps IEC 61549: 2003 |
2016/08/07 |
|
EN 61549: 2003 / A1: 2005 IEC 61549: 2003 / A1: 2005 |
|
|
EN 61549: 2003 / A2: 2010 IEC 61549: 2003 / A2: 2010 |
|
|
EN 61549: 2003 / A3: 2012 IEC 61549: 2003 / A3: 2012 |
2016/08/07 |
CENELEC |
IN 61557-1: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 1: General requirements IEC 61557-1: 2007 |
2016/08/07 |
CENELEC |
IN 61557-2: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 2: Insulation resistance IEC 61557-2: 2007 |
2016/08/07 |
CENELEC |
IN 61557-3: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 3: Loop impedance IEC 61557-3: 2007 |
2016/08/07 |
CENELEC |
IN 61557-4: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 4: Resistance and equipotential bonding of the ground connection IEC 61557-4: 2007 |
2016/08/07 |
CENELEC |
IN 61557-5: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 5: Earth resistance IEC 61557-5: 2007 |
2016/08/07 |
CENELEC |
IN 61557-6: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 6: Efficiency of residual current devices (RCD) in TT, TN and IT systems IEC 61557-6: 2007 |
2016/08/07 |
CENELEC |
IN 61557-7: 2007 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 7: Phase sequence IEC 61557-7: 2007 |
2016/08/07 |
CENELEC |
IN 61557-10: 2013 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 10: Combined measuring devices for testing, measuring or monitoring protective measures IEC 61557-10: 2013 |
2016/08/07 |
CENELEC |
IN 61557-11: 2009 1 000 V Electrical safety in low voltage distribution systems from AC and 1 to 500 Vdc - test equipment, measuring or monitoring of protective measures - Part 11: TT, TN leakage current monitors Efficiency (RCMS) type A and type B and IT systems IEC 61557-11: 2009 |
2016/08/07 |
CENELEC |
IN 61557-12: 2008 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 12: Performance measuring and monitoring devices (PMD) IEC 61557-12: 2007 |
2016/08/07 |
CENELEC |
IN 61557-13: 2011 1 000 V Electrical safety in low voltage distribution systems from AC and 1 to 500 Vdc - test equipment, measuring or monitoring of protective measures - Part 13: Current distribution of clamps and sensors for hand and hand electrical distribution systems for measuring leakage currents IEC 61557-13: 2011 |
2016/08/07 |
CENELEC |
IN 61557-14: 2013 Electrical safety in low voltage distribution systems up to 1 000 V ac and 1 500 V dc - Equipment for testing, measuring or monitoring protective measures - Part 14: Equipment for testing the safety of machine electrical equipment IEC 61557-14: 2013 |
2016/08/07 |
CENELEC |
IN 61558-1: 2005 Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests IEC 61558-1: 2005 |
2016/08/07 |
|
EN 61558-1: 2005 / A1: 2009 IEC 61558-1: 2005 / A1: 2009 |
2016/08/07 |
|
EN 61558-1: 2005 / AC: 2006 |
|
CENELEC |
EN 61558-2-1: 2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies including disconnecting transformers for general applications IEC 61558-2-1: 2007 |
2016/08/07 |
CENELEC |
EN 61558-2-2: 2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-2: Specific requirements and tests for power supplies including control transformers and control transformers IEC 61558-2-2: 2007 |
2016/08/07 |
CENELEC |
EN 61558-2-3: 2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-3: Specific requirements and tests for ignition transformers for gas and oil burners IEC 61558-2-3: 2010 |
2016/08/07 |
CENELEC |
EN 61558-2-4: 2009 1 100 V - Part Safety of transformer, reactor, power supply units and similar products for supply voltages up to 2-4: Special requirements and tests for the isolation of transformer and power supply units containing insulators IEC 61558-2-4: 2009 |
2016/08/07 |
CENELEC |
EN 61558-2-5: 2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-5: Specific requirements and tests for power supply units for shavers, transformers, shavers and shaver supply units IEC 61558-2-5: 2010 |
2016/08/07 |
CENELEC |
EN 61558-2-6: 2009 1 100 V - Part Safety of transformers, reactors, power supply units and similar products for supply voltages up to 2-6: Specific requirements and tests for safety isolation transformers and power supply units with safety insulated transformers IEC 61558-2-6: 2009 |
2016/08/07 |
CENELEC |
EN 61558-2-7: 2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-7: Specific requirements and tests for transformers and power supplies for toys IEC 61558-2-7: 2007 (Replaced) |
2016/08/07 |
CENELEC |
EN 61558-2-8: 2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-8: Specific requirements and tests for transformer and power supply units for bells and bells IEC 61558-2-8: 2010 |
2016/08/07 |
CENELEC |
EN 61558-2-9: 2011 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-9: Particular requirements and tests for transformer and power supply units for class III flashlights for tungsten filament lamps IEC 61558-2-9: 2010 |
2016/08/07 |
CENELEC |
EN 61558-2-12: 2011 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-12: Specific requirements and tests for constant voltage transformers and power supply units for constant voltage IEC 61558-2-12: 2011 |
2016/08/07 |
CENELEC |
EN 61558-2-13: 2009 1 100 V - Part Safety of transformer, reactor, power supply units and similar products for supply voltages up to 2-13: Specific requirements and tests for power supply units including automatic transformers and auto transformers IEC 61558-2-13: 2009 |
2016/08/07 |
CENELEC |
EN 61558-2-14: 2013 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-14: Specific requirements and tests for variable transformers and power supply units containing variable transformers IEC 61558-2-14: 2012 |
2016/08/07 |
CENELEC |
EN 61558-2-15: 2012 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for the isolation of transformers for the supply of medical facilities IEC 61558-2-15: 2011 |
2016/08/07 |
CENELEC |
EN 61558-2-16: 2009 1 100 V - Part Safety of transformer, reactor, power supply units and similar products for supply voltages up to 2-16: Specific requirements and tests for switched power supply units and transformers for switching power supply units IEC 61558-2-16: 2009 |
2016/08/07 |
|
EN 61558-2-16: 2009 / A1: 2013 IEC 61558-2-16: 2009 / A1: 2013 |
2016/08/07 |
CENELEC |
EN 61558-2-20: 2011 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-20: Specific requirements and tests for small reactors IEC 61558-2-20: 2010 |
2016/08/07 |
CENELEC |
EN 61558-2-23: 2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-23: Specific requirements and tests for transformer and power supply units for construction sites IEC 61558-2-23: 2010 |
2016/08/07 |
CENELEC |
EN 61558-2-26: 2013 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-26: Specific requirements and tests for transformer and power supply units for energy and other purposes IEC 61558-2-26: 2013 |
2016/08/07 |
CENELEC |
IN 61643-11: 2012 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods IEC 61643-11: 2011 (Changed) |
2016/08/07 |
CENELEC |
IN 61643-21: 2001 Low-voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signaling networks - Performance requirements and test methods IEC 616 IEC 61643-21: 2000 |
2016/08/07 |
|
EN 61643-21: 2001 / A1: 2009 IEC 61643-21: 2000 / A1: 2008 (Changed) |
|
|
EN 61643-21: 2001 / A2: 2013 IEC 61643-21: 2000 / A2: 2012 |
2016/08/07 |
CENELEC |
IN 61730-1: 2007 Photovoltaic (PV) module safety qualification - Part 1: Construction requirements IEC 61730-1: 2004 (Replaced) |
2016/08/07 |
|
EN 61730-1: 2007 / A1: 2012 IEC 61730-1: 2004 / A1: 2011 |
|
|
EN 61730-1: 2007 / A2: 2013 IEC 61730-1: 2004 / A2: 2013 |
|
|
EN 61730-1: 2007 / A11: 2014 |
2016/08/07 |
CENELEC |
IN 61730-2: 2007 Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing IEC 61730-2: 2004 (Replaced) |
2016/08/07 |
|
EN 61730-2: 2007 / A1: 2012 IEC 61730-2: 2004 / A1: 2011 |
2016/08/07 |
CENELEC |
AND 61770: 2009 Power tools connected to the water supply - Rear seat avoidance and failure of hose assemblies IEC 61770: 2008 |
2016/08/07 |
|
EN 61770: 2009 / AC: 2011 |
|
CENELEC |
EN 61800-5-1: 2007 Adjustable fast electrical power systems - Part 5-1: Safety requirements - Electricity, heat and energy IEC 61800-5-1: 2007 |
2016/08/07 |
CENELEC |
IN 61812-1: 2011 Time relays for industrial and residential use - Part 1: Requirements and tests IEC 61812-1: 2011 |
2016/08/07 |
CENELEC |
IN 61851-1: 2011 Electric vehicle conductor charging system - Part 1: General requirements IEC 61851-1: 2010 |
2016/08/07 |
CENELEC |
IN 61851-21: 2002 Electric vehicle conductive charging system - Part 21: Electrical vehicle requirements for conductor connection to an ac / dc source IEC 61851-21: 2001 |
2016/08/07 |
CENELEC |
IN 61851-22: 2002 Electric vehicle conductor charging system - Part 22: AC electric vehicle charging station IEC 61851-22: 2001 |
2016/08/07 |
CENELEC |
IN 61851-23: 2014 Electric vehicle conductor charging system - Part 23: DC electric vehicle charging station IEC 61851-23: 2014 |
2016/08/07 |
CENELEC |
IN 61851-24: 2014 Electric vehicle conductor charging system - Part 24: Digital communication between a dc EV charging station and an electric vehicle for controlling DC charge IEC 61851-24: 2014 |
2016/08/07 |
|
EN 61851-24: 2014 / AC: 2015 |
|
CENELEC |
IN 61869-1: 2009 Instrument transformers - Part 1: General requirements IEC 61869-1: 2007 (Replaced) |
2016/08/07 |
CENELEC |
IN 61869-2: 2012 Instrument transformers - Part 2: Additional requirements for current transformers IEC 61869-2: 2012 |
2016/08/07 |
CENELEC |
IN 61869-3: 2011 Instrument transformers - Part 3: Additional requirements for inductive voltage transformers IEC 61869-3: 2011 |
2016/08/07 |
CENELEC |
IN 61869-4: 2014 Instrument transformers - Part 4: Additional requirements for combined transformers IEC 61869-4: 2013 |
2016/08/07 |
|
EN 61869-4: 2014 / AC: 2014 |
|
CENELEC |
IN 61869-5: 2011 Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers IEC 61869-5: 2011 |
2016/08/07 |
|
EN 61869-5: 2011 / AC: 2015 |
|
CENELEC |
AND 61914: 2016 Cable clamps for electrical installations IEC 61914: 2015 |
2016/08/07 |
CENELEC |
AND 61921: 2003 Power capacitors - Low voltage power factor correction banks IEC 61921: 2003 |
2016/08/07 |
CENELEC |
IN 61995-1: 2008 Devices for the connection of domestic and similar luminaires - Part 1: General requirements IEC 61995-1: 2005 (Replaced) |
2016/08/07 |
CENELEC |
IN 61995-2: 2009 Devices for connecting domestic and similar luminaires - Part 2: Standard pages for DCL IEC 61995-2: 2009 |
2016/08/07 |
CENELEC |
AND 62020: 1998 Electrical accessories - Residual current monitors for home and similar uses (RCMs) IEC 62020: 1998 |
2016/08/07 |
|
EN 62020: 1998 / A1: 2005 IEC 62020: 1998 / A1: 2003 (Replaced) |
2016/08/07 |
CENELEC |
IN 62026-1: 2007 Low-voltage switchgear and control - Controller-device interfaces (CDIs) - Part 1: General rules IEC 62026-1: 2007 |
2016/08/07 |
CENELEC |
IN 62026-2: 2013 Low-voltage switchgear and controllers - Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i) IEC 62026-2: 2008 (Changed) |
2016/08/07 |
CENELEC |
IN 62026-3: 2015 Low-voltage switchgear and control - Controller-device interfaces (CDIs) - Part 3: DeviceNet IEC 62026-3: 2014 IEC 62026-3: 2014 / COR1: 2015 |
2016/08/07 |
CENELEC |
IN 62026-7: 2013 Low-voltage switchgear and controllers - Controller-device interfaces (CDIs) - Part 7: CompoNet IEC 62026-7: 2010 (Changed) |
2016/08/07 |
CENELEC |
AND 62031: 2008 LED modules for general lighting - Safety features IEC 62031: 2008 |
2016/08/07 |
|
EN 62031: 2008 / A1: 2013 IEC 62031: 2008 / A1: 2012 |
|
|
EN 62031: 2008 / A2: 2015 IEC 62031: 2008 / A2: 2014 |
2016/08/07 |
CENELEC |
AND 62035: 2014 Discharge lamps (excluding fluorescent lamps) - Safety features IEC 62035: 2014 (Changed) |
2016/08/07 |
CENELEC |
IN 62040-1: 2008 Uninterruptible power systems (UPS) - Part 1: General and safety requirements for UPS IEC 62 IEC 62040-1: 2008 |
2016/08/07 |
|
EN 62040-1: 2008 / A1: 2013 IEC 62040-1: 2008 / A1: 2013 |
2016/08/07 |
|
EN 62040-1: 2008 / AC: 2009 |
|
CENELEC |
AND 62080: 2009 Audio signaling equipment for home and similar purposes IEC 62080: 2001 + A1: 2008 |
2016/08/07 |
CENELEC |
IN 62094-1: 2003 Indicator light units for household and similar fixed electrical installations - Part 1: General requirements IEC 62094-1: 2002 |
2016/08/07 |
|
EN 62094-1: 2003 / A11: 2003 |
2016/08/07 |
CENELEC |
IN 62109-1: 2010 Safety of power converters for use in photovoltaic power systems - Part 1: General requirements IEC 62109-1: 2010 |
2016/08/07 |
CENELEC |
IN 62109-2: 2011 Safety of power converters for use in photovoltaic power systems - Part 2: Special requirements for inverters IEC 62109-2: 2011 |
2016/08/07 |
CENELEC |
IN 62135-1: 2015 Resistance welding equipment - Part 1: Safety requirements for design, manufacture and installation IEC 62135-1: 2015 |
2016/08/07 |
CENELEC |
IN 62196-1: 2014 Plugs, sockets, vehicle sockets and vehicle inputs - Conductive charging of electric vehicles - Part 1: General requirements IEC 62196-1: 2014 (Replaced) |
2016/08/07 |
CENELEC |
IN 62196-2: 2012 Plugs, sockets, vehicle sockets and vehicle inlets - Conductive charging of electric vehicles - Part 2: Dimensional compatibility and interchangeability requirements for AC pin and contact pipe accessories IEC 62196-2: 2011 |
2016/08/07 |
|
EN 62196-2: 2012 / A11: 2013 |
2016/08/07 |
|
EN 62196-2: 2012 / A12: 2014 |
2016/08/07 |
CENELEC |
IN 62196-3: 2014 Plugs, socket outlets, vehicle connections and vehicle inputs - Conductive charging of electric vehicles - Part 3: Dimensional compatibility and interchangeability requirements for DC and AC / DC pin and contact pipe vehicle connections IEC 62196-3: 2014 |
2016/08/07 |
CENELEC |
AND 62208: 2011 Empty housings for low voltage switchgear and control panels - General requirements IEC 62208: 2011 |
2016/08/07 |
CENELEC |
AND 62233: 2008 Measurement methods for electromagnetic fields of household appliances and similar devices for human exposure IEC 62233: 2005 (Changed) |
2016/08/07 |
|
EN 62233: 2008 / AC: 2008 |
|
CENELEC |
AND 62253: 2011 Photovoltaic pump systems - Design competence and performance measurements IEC 62253: 2011 |
2016/08/07 |
CENELEC |
AND 62275: 2015 Cable management systems - ties for electrical installations IEC 62275: 2013 (Changed) |
2016/08/07 |
CENELEC |
EN 62282-3-100: 2012 Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety IEC 62282-3-100: 2012 |
2016/08/07 |
CENELEC |
EN 62282-3-300: 2012 Fuel cell technologies - Part 3-300: Stationary fuel cell power systems - Installation IEC 62282-3-300: 2012 |
2016/08/07 |
CENELEC |
EN 62282-5-1: 2012 Fuel cell technologies - Part 5-1: Portable fuel cell power systems - Safety IEC 62282-5-1: 2012 |
2016/08/07 |
CENELEC |
IN 62310-1: 2005 Static transfer systems (STS) - Part 1: General and safety requirements IEC 62310-1: 2005 |
2016/08/07 |
CENELEC |
AND 62311: 2008 Assessment of electronic and electrical equipment for human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz) IEC 62311: 2007 (Changed) |
2016/08/07 |
CENELEC |
IN 62368-1: 2014 Audio / video, information and communication technology equipment - Part 1: Safety requirements (IEC 62368-1: 2014, modified) IEC 62368-1: 2014 (Changed) |
2016/08/07 |
|
EN 62368-1: 2014 / AC: 2015 |
|
CENELEC |
IN 62395-1: 2013 Electrical resistance track heating systems for industrial and commercial applications - Part 1: General and test requirements IEC 62395-1: 2013 |
2016/08/07 |
CENELEC |
AND 62423: 2012 Non-integrated type F and type B residual current switches with internal overcurrent protection for household and similar uses IEC 62423: 2009 (Changed) |
2016/08/07 |
CENELEC |
AND 62444: 2013 Cable glands for electrical installations IEC 62444: 2010 (Changed) |
2016/08/07 |
CENELEC |
AND 62471: 2008 Photobiological safety of lamps and lamp systems IEC 62471: 2006 (Changed) |
2016/08/07 |
CENELEC |
IN 62477-1: 2012 Safety requirements for power electronic converter systems and equipment - Part 1: General IEC 62477-1: 2012 |
2016/08/07 |
|
EN 62477-1: 2012 / A11: 2014 |
2016/08/07 |
CENELEC |
AND 62479: 2010 Evaluating the compliance of low power electronic and electrical equipment with the basic restrictions on exposure to electromagnetic fields (10 MHz to 300 GHz) IEC 62479: 2010 (Changed) |
2016/08/07 |
CENELEC |
AND 62493: 2010 Evaluation of lighting equipment related to human exposure to electromagnetic fields IEC 62493: 2009 |
2016/08/07 |
CENELEC |
AND 62532: 2011 Fluorescent induction lamps - Safety features IEC 62532: 2011 |
2016/08/07 |
CENELEC |
AND 62549: 2011 Articulated and flexible systems for cable guidance IEC 62549: 2011 |
2016/08/07 |
CENELEC |
AND 62560: 2012 Self-ballasted LED lamps for voltage> 50 V general lighting services - Safety features IEC 62560: 2011 (Changed) |
2016/08/07 |
|
EN 62560: 2012 / A1: 2015 IEC 62560: 2011 / A1: 2015 (Replaced) |
2016/08/07 |
|
EN 62560: 2012 / A1: 2015 / AC: 2015 |
|
|
EN 62560: 2012 / AC: 2015 |
|
CENELEC |
AND 62606: 2013 General requirements for arc fault detection devices IEC IEC 62606: 2013 (Changed) |
2016/08/07 |
CENELEC |
IN 62626-1: 2014 Low-voltage switchgear and control devices closed - Part 1: Closed circuit disconnectors outside the scope of IEC 60947-3, for isolation during repair and maintenance work IEC 62626-1: 2014 |
2016/08/07 |
CENELEC |
HD 62640: 2015 Residual current devices for overcurrent protection or overcurrent protection for sockets for household and similar uses IEC 62640: 2011 (Changed) |
2016/08/07 |
CENELEC |
AND 62776: 2015 Double cover LED lamps designed to reinforce linear fluorescent lamps - Safety features IEC 62776: 2014 IEC 62776: 2014 / COR1: 2015 |
2016/08/07 |
CENELEC |
AND 62868: 2015 Organic light emitting diode (OLED) panels for general lighting - Safety requirements IEC 62868: 2014 |
2016/08/07 |